LiChrospher® HPLC Columns
LiChrospher® HPLC columns are known for their reliable, fully porous spherical silica-based sorbent, which is recognized for its trusted performance in thousands of HPLC methods throughout various application fields. The sorbent is produced traditionally with various modifications, allowing it to adapt to different chromatographic needs.
The non-polar modified phases LiChrospher® RP-8, RP-8 endcapped, RP-select B, RP-18, RP-18 endcapped are made for reversed-phase separations.
For the normal phase the polar modified phases, such as LiChrospher® CN, LiChrospher® NH2, and LiChrospher® DIOL, as well as the unmodified LiChrospher® SI, are well-suited.
Additionally, LiChrospher® PAH is renowned for its high selectivity in separating polycyclic aromatic hydrocarbons (PAHs).
LiChrospher® packing materials are available in Hibar® RT ready-to-use columns and LiChroCART® cartridges, offering a variety of lengths and internal diameters (10 mm, 4.6 mm, 4 mm, 3 mm, and 2 mm). The narrow-bore LiChroCART® cartridges (3 mm I.D. and 2 mm I.D.) offer significant benefits for HPLC by minimizing solvent consumption, decreasing operational costs, and improving sensitivity and resolution. Additionally, LiChroCART® cartridges with internal diameters of 4.6 mm, 4 mm, 3 mm, and 2 mm are compatible with the manu-CART® NT system, enabling faster and more adaptable method adjustments for smaller bore columns. The LiChroCART® cartridges, with a 10 mm internal diameter, are specifically designed for larger-scale applications and are compatible with the manu-CART® “10”-II system.
Packing | USP Designation | Characteristics/Phase | Pore size (Å) | Particle | % C | Endcapped |
---|---|---|---|---|---|---|
LiChrospher® 100 RP-18 | L1 | Spherical particles of silica with octadecyl derivative | 100 | 5, 10 | 21.0 | no |
LiChrospher®RP-18 endcapped | L1 | Spherical particles of silica with octadecyl derivative endcapped | 100 | 5, 10 | 21.6 | yes |
LiChrospher® PAH | L1 | Spherical particles of silica with octadecyl derivative | 150 | 5 | proprietary | no |
LiChrospher® 100 RP-8 | L7 | Spherical particles of silica with octyl derivative | 100 | 5, 10 | 12.5 | no |
LiChrospher® 100 RP-8 endcapped | L7 | Spherical particles of silica with octyl derivative endcapped | 100 | 5, 10 | 13.0 | yes |
LiChrospher® RP-select B | L7 | Octylsilane deactivated for the separation of basic compounds | 60 | 5, 10 | 11.5 | no |
LiChrospher® 100 DIOL | L20 | Spherical particles of silica with vicinal hydroxyl function on C-chains | 100 | 5 | 8.0 | no |
LiChrospher® 100 NH2 | L8 | Spherical particles of silica with aminopropyl function | 100 | 5 | 4.6 | no |
LiChrospher® 100 CN | L10 | Spherical particles of silica with cyanopropyl function | 100 | 5, 10 | 6.6 | no |
LiChrospher® Si 60 | L3 | Spherical particles of silica | 60 | 5, 10 | n.a. | n.a. |
LiChrospher® Si 100 |
| Spherical particles of silica | 100 | 5 | n.a. | n.a. |
LiChrospher® 60 RP-select B |
| Spherical particles of silica with octyl derivative, especially suitable for the RP separation of basic compounds | 60 | 5,10 | 11.5 | no |
LiChrospher® 100 RP-18 and RP-18 endcapped HPLC Columns
LiChrospher® 100 RP-18 and RP-18 endcapped HPLC columns are very reliable and highly versatile C18 phases. These traditionally manufactured spherical silica-based supports are intended for reversed-phase chromatography of acidic, neutral, and weakly basic compounds—substances commonly encountered across various analytical fields. Several individual batches are utilized to create a large master batch of the LiChrospher® RP-18 sorbent. This removes discrepancies among various small batches and guarantees the sorbent's outstanding consistency from one batch to another. As a result, LiChrospher® RP-18 provides consistently reproducible outcomes, ensuring the reliability of your HPLC method.
LiChrospher® RP-18 HPLC Columns are classified as USP L1 columns, meeting the stringent requirements for reversed-phase chromatography and ensuring consistent, high-quality separations in pharmaceutical and analytical applications.
Specifications of LiChrospher® 100 RP-18 and RP-18 endcapped HPLC Columns
| LiChrospher® 100 RP-18 | LiChrospher® 100 RP-18 endcapped |
---|---|---|
Sorbent characteristics | Particles of silica with octadecyl derivative | Particles of silica with octadecyl derivative endcapped |
Particle shape | Fully porous spherical silica particles (Type A) | Fully porous spherical silica particles (Type A) |
Particle size | 5, 10 μm | 5, 10 μm |
Pore size | 100 Å (10 nm) | 100 Å (10 nm) |
Pore volume | 1.25 mL/g | 1.25 mL/g |
Spec. surface area | 350 m2/g | 350 m2/g |
Carbon load | 21.0 % C | 21.6 % C |
Coverage of the surface | 4,09 μmol/m2 | 4.09 μmol/m2 |
Minimum Efficiency | 50,000 N/m (5 µm); | 55,000 N/m (5 µm); |
pH range | 2-7.5 | 2-7.5 |
Shipping eluent | Acetonitrile/water | Acetonitrile/water |
LiChrospher® 100 RP-8 and RP-8 endcapped HPLC Columns
LiChrospher® 100 RP-8 and RP-8 endcapped HPLC columns are made from spherical silica gel carriers that exhibit C8 or C8 endcapped reversed-phase characteristics. The columns demonstrate exceptional versatility, making them appropriate for acidic, neutral, and weakly basic compounds. The columns provide excellent selectivity and performance, guaranteeing consistent separations across different batches and over the years.
Specifications of LiChrospher® 100 RP-8 and RP-8 endcapped
| LiChrospher® 100 RP-8 | LiChrospher® 100 RP-8 endcapped |
---|---|---|
Sorbent characteristics | Particles of silica with octyl derivative | Particles of silica with octyl derivative endcapped |
Particle shape | Fully porous spherical silica particles (Type A) | Fully porous spherical silica particles (Type A) |
Particle size | 5, 10 μm | 5, 10 μm |
Pore size | 100 Å (10 nm) | 100 Å (10 nm) |
Pore volume | 1.25 mL/g | 1.25 mL/g |
Spec. surface area | 350 m2/g | 350 m2/g |
Carbon load | 12.5 % C | 13 % C |
Coverage of the surface | 4.04 μmol/m2 | 4.44 μmol/m2 |
Minimum Efficiency | 55,000 N/m (5 µm); | 55,000 N/m (5 µm); |
pH range | 2-7.5 | 2-7.5 |
Shipping eluent | Acetonitrile/water | Acetonitrile/water |
LiChrospher® 60 RP-Select B HPLC Columns
LiChrospher® 60 RP-Select B is designed specifically for HPLC separations of basic compounds. The sorbent, derived from spherical silica particles, effectively prevents secondary interactions with basic substances, ensuring their elution as highly symmetrical peaks. In addition to providing outstanding separation properties for basic compounds, LiChrospher® 60 RP-Select B is also appropriate for the analysis of neutral and acidic substances. For LiChrospher® RP-select B, multiple individual batches are utilized to create a large master batch of the sorbent. This removes discrepancies among various small batches and guarantees the sorbent's outstanding consistency from one batch to another. As a result, LiChrospher® RP-select B column provides exceptionally consistent outcomes, ensuring the dependability of your HPLC method.
The exceptional reproducibility of the “master batch LiChrospher® RP-select B" in comparison to smaller individual batches of the sorbent is clearly evidenced by the Tanaka test, a rigorous HPLC column testing procedure.
Specifications of LiChrospher® 60 RP-Select B
Sorbent characteristics | Particles of silica with octyl derivative |
---|---|
Particle shape | Fully porous spherical silica particles (Type A) |
Particle size | 5 μm |
Pore size | 60 Å (6 nm) |
Pore volume | 0.9 mL/g |
Spec. surface area | 360 m2/g |
Carbon load | 11.5 % C |
Coverage of the surface | 3.55 μmol/m2 |
Minimum Efficiency | 55,000 N/m; |
pH range | 2-7.5 |
Shipping eluent | Acetonitrile/water |
LiChrospher® 100 DIOL HPLC Columns
LiChrospher® 100 DIOL has both polar and hydrophobic characteristics, combining weak hydrophobic interactions with polar interactions. This allows for successful HPLC separation of complex samples. The sorbent can be employed as a less polar alternative to LiChrospher® Si 60 in normal-phase applications, as well as a less hydrophobic alternative (with some limits) to LiChrospher® RP-8 in reversed-phase applications. Furthermore, LiChrospher® DIOL is suitable for HILIC chromatography.
Specifications of LiChrospher® 100 DIOL
Sorbent characteristics | Particles of silica with diol function on C-chains |
---|---|
Particle shape | Fully porous spherical silica particles (Type A) |
Particle size | 5 μm |
Pore size | 100 Å (10 nm) |
Pore volume | 1.25 mL/g |
Spec. surface area | 350 m2/g |
Carbon load | 8.0 % C |
Coverage of the surface | 3.87 μmol/m2 |
Minimum Efficiency | 40,000 N/m |
pH range | 2-7.5 |
Shipping eluent | n-Heptane |
LiChrospher® 100 NH2 HPLC Columns
LiChrospher® NH2 is a versatile sorbent that features both polar and hydrophobic characteristics. This makes it appropriate for normal-phase, reversed-phase, HILIC, and ion exchange chromatography. Common applications involve the separation of carbohydrates (mono-, di-, and oligosaccharides) using reversed-phase chromatography, as well as the separation of nucleotides through ion exchange chromatography.
Specifications of LiChrospher® 100 NH2
Sorbent characteristics | Particles of silica with gamma-aminopropyl function |
---|---|
Particle shape | Fully porous spherical silica particles (Type A) |
Particle size | 5 μm |
Pore size | 100 Å (10 nm) |
Pore volume | 1.25 mL/g |
Spec. surface area | 350 m2/g |
Carbon load | 4.6 % C |
Coverage of the surface | 4.1 μmol/m2 |
Minimum Efficiency | 25000 N/m |
pH range | 2-7.5 |
Shipping eluent | n-Heptane |
LiChrospher® 100 CN HPLC Columns
LiChrospher® 100 CN exhibits a unique combination of polar and hydrophobic properties, integrating weak hydrophobic interactions alongside polar interactions. This facilitates effective HPLC separations of intricate samples. The sorbent is a less polar option than LiChrospher® Si 60 for normal-phase applications or a less hydrophobic choice relative to LiChrospher® RP-8 for reversed-phase applications. This adaptable sorbent is also appropriate for selective charged interactions.
Specifications of LiChrospher® 100 CN
Sorbent characteristics | Particles of silica with gamma-cyanopropyl function |
---|---|
Particle shape | Fully porous spherical silica particles (Type A) |
Particle size | 5, 10 μm |
Pore size | 100 Å (10 nm) |
Pore volume | 1.25 mL/g |
Spec. surface area | 350 m2/g |
Carbon load | 6.6 % C |
Coverage of the surface | 3.52 μmol/m2 |
Minimum Efficiency | 40,000 N/m (5 µm); |
pH range | 2-7.5 |
Shipping eluent | n-Heptane |
Specifications of LiChrospher® Si 60 and Si 100
| LiChrospher® Si 60 | LiChrospher® Si 100 |
---|---|---|
Sorbent characteristics | Particles of silica | Particles of silica |
Particle shape | Fully porous spherical silica particles (Type A) | Fully porous spherical silica particles (Type A) |
Particle size | 5, 10 μm | 5 μm |
Pore size | 60 Å (10 nm) | 100 Å (10 nm) |
Pore volume | 0.85 mL/g | 1.25 mL/g |
Spec. surface area | 700 m2/g | 400 m2/g |
Minimum Efficiency | 55,000 N/m (5 µm); | 55,000 N/m |
pH range | 2-7.5 | 2-7.5 |
Shipping eluent | n-Heptane | n-Heptane |
LiChrospher® PAH HPLC Columns
LiChrospher® PAH is a highly selective HPLC column, built specifically for the trace analysis of PAH. The column delivers outstanding, high-resolution gradient separations of 16 PAH in accordance with EPA 610 and EPA 550, in addition to benzo[e]pyrene and perylene. Further, the LiChrospher® PAH columns are well-suited for the isocratic separation of 6 PAHs in accordance with the German DIN method. They incorporate programmed fluorescence detection, enabling precise and sensitive analysis. During typical runs, the first eluting polycyclic aromatic hydrocarbon (PAH), naphthalene, appears at approximately 10 minutes, with full separation completed within 30 minutes.
Specifications of LiChrospher® PAH HPLC Columns
Sorbent characteristics | Particles of silica with octadecyl derivative |
---|---|
Particle shape | Fully porous spherical silica particles (Type A) |
Particle size | 5 μm |
Pore size | 150 Å (15 nm) |
Spec. surface area | 200 m2/g |
Carbon load | 20 % |
pH range | 2-7.5 |
Shipping eluent | Acetonitrile/water |
LiChrospher® HPLC Columns with 5 µm Particle Size in column hardware LiChroCART® Cartridge (manu-CART® required) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Column dimension |
|
|
|
|
|
|
|
|
|
|
| ||
Length (mm) |
| ID (mm) | RP-18 (5 µm) | RP-18 endcapped (5 µm) | PAH (5 µm) | RP-8 (5 µm) | RP-8 endcapped (5 µm) | RP-select B (5 µm) | Diol (5 µm) | CN (5 µm) | NH2 (5 µm) | Si 60 (5 µm) | Si 100 (5 µm) |
25 | x | 4 | on request | ||||||||||
55 | x | 2 |
|
|
| ||||||||
75 | x | 4 | on request | on request |
| ||||||||
100 | x | 4.6 | |||||||||||
125 | x | 3 |
| on request | on request | ||||||||
125 | x | 4 | |||||||||||
125 | x | 4 | on request | ||||||||||
125 | x | 4.6 | on request | on request | on request | on request | |||||||
150 | x | 4.6 | |||||||||||
250 | x | 3 | on request | on request | on request |
| |||||||
250 | x | 4 | |||||||||||
250 | x | 4 | on request | ||||||||||
250 | x | 4.6 |
|
| |||||||||
100 | x | 4.6 | |||||||||||
125 | x | 3 | |||||||||||
125 | x | 4 | |||||||||||
125 | x | 4.6 |
|
|
| ||||||||
150 | x | 4.6 |
| ||||||||||
250 | x | 3 | |||||||||||
250 | x | 4 | |||||||||||
250 | x | 4.6 |
|
| |||||||||
4 | x | 4 | |||||||||||
* 3 units The LiChroCART® columns (75, 100, 125, 150, and 250 mm length) in the list above (2, 3, 4, and 4.6 mm I.D.) require part number 1.51486.0001 manu-CART® cartridge column holder, which can be used to hold one cartridge column with or without a 4-4 mm guard column. LiChroCART® columns 250-10 mm require part number 1.51419.0001 manu-CART® 10. Additional dimensions and validation kits are available as customized packings on request. |
LiChrospher® HPLC Columns with 5 µm Particle Size in Hibar® RT column hardware | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Column dimension |
|
|
|
|
|
|
|
|
|
|
| ||
Length (mm) |
| ID (mm) | RP-18 (5 µm) | RP-18 endcapped (5 µm) | PAH (5 µm) | RP-8 (5 µm) | RP-8 endcapped (5 µm) | RP-select B (5 µm) | Diol (5 µm) | CN (5 µm) | NH2 (5 µm) | Si 60 (5 µm) | Si 100 (5 µm) |
Hibar® RT HPLC Column [1 unit] | |||||||||||||
50 | x | 4 |
|
|
|
|
|
|
|
|
|
|
|
100 | x | 4.6 |
|
|
|
|
| ||||||
125 | x | 2 | on request | on request | on request | on request |
|
|
|
|
| ||
125 | x | 4 | on request |
| on request | on request | on request |
|
|
|
|
| |
125 | x | 4.6 | on request | on request | on request | on request |
|
|
|
|
| ||
150 | x | 3 |
|
|
|
|
|
|
|
|
|
|
|
150 | x | 4.6 |
|
| |||||||||
250 | x | 3 |
|
|
|
|
|
|
|
|
|
|
|
250 | x | 4 | on request | on request | on request | on request |
|
|
|
| |||
250 | x | 4.6 |
|
| |||||||||
Validation Kits [3 Hibar® RT HPLC Columns from 3 different sorbent batches] | |||||||||||||
100 | x | 4.6 |
|
|
|
|
| ||||||
125 | x | 4 |
|
|
|
|
|
|
|
|
| ||
150 | x | 4.6 |
|
|
|
|
|
|
| ||||
250 | x | 4 |
|
|
|
|
|
|
| ||||
240 | x | 4.6 |
|
|
|
|
|
|
|
|
| ||
The Hibar® columns are complete with endfittings. When using a guard column with a Hibar® column, we recommend part number 1.51487.0001 guard column cartridge holder for 4-4 mm guard column LiChroCART® cartridges. Additional dimensions are available as customized packings on request. |
LiChrospher® HPLC Columns with 10 µm Particle Size in column hardware LiChroCART® Cartridge (manu-CART® required)
Column dimension |
| |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Length (mm) |
| ID (mm) | RP-18 (10 µm) | RP-18 endcapped (10 µm) | RP-8 (10 µm) | RP-8 endcapped (10 µm) | RP-select B (10 µm) | Diol (10 µm) | CN (10 µm) | NH2 (10 µm) | Si 60 (10 µm) |
|
LiChroCART® HPLC Cartridge [1 unit; * 3 units] | ||||||||||||
10 | x | 10 |
|
|
|
|
|
|
|
|
|
|
250 | x | 4 | on request |
|
| |||||||
250 | x | 4.6 |
|
|
|
|
|
|
|
|
|
|
250 |
| 10 | on request |
| on request | on request | on request | on request |
| |||
The LiChroCART® columns (75, 100, 125, 150, and 250 mm length) in the list above (2, 3, 4, and 4.6 mm I.D.) require part number 1.51486.0001 manu-CART® cartridge column holder, which can be used to hold one cartridge column with or without a 4-4 mm guard column. LiChroCART® columns 250-10 mm require part number 1.51419.0001 manu-CART® 10. Additional dimensions and validation kits are available as customized packings on request. |
LiChrospher® HPLC Columns with 10 µm Particle Size in Hibar® RT Column Hardware are available on request.
To continue reading please sign in or create an account.