Skip to Content
Merck
HomeSmall Molecule HPLCLiChrospher® HPLC Columns

LiChrospher® HPLC Columns

LiChrospher® HPLC columns are known for their reliable, fully porous spherical silica-based sorbent, which is recognized for its trusted performance in thousands of HPLC methods throughout various application fields. The sorbent is produced traditionally with various modifications, allowing it to adapt to different chromatographic needs.

The non-polar modified phases LiChrospher® RP-8, RP-8 endcapped, RP-select B, RP-18, RP-18 endcapped are made for reversed-phase separations.

For the normal phase the polar modified phases, such as LiChrospher® CN, LiChrospher® NH2, and LiChrospher® DIOL, as well as the unmodified LiChrospher® SI, are well-suited.

Additionally, LiChrospher® PAH is renowned for its high selectivity in separating polycyclic aromatic hydrocarbons (PAHs).

LiChrospher® packing materials are available in Hibar® RT ready-to-use columns and LiChroCART® cartridges, offering a variety of lengths and internal diameters (10 mm, 4.6 mm, 4 mm, 3 mm, and 2 mm). The narrow-bore LiChroCART® cartridges (3 mm I.D. and 2 mm I.D.) offer significant benefits for HPLC by minimizing solvent consumption, decreasing operational costs, and improving sensitivity and resolution. Additionally, LiChroCART® cartridges with internal diameters of 4.6 mm, 4 mm, 3 mm, and 2 mm are compatible with the manu-CART® NT system, enabling faster and more adaptable method adjustments for smaller bore columns. The LiChroCART® cartridges, with a 10 mm internal diameter, are specifically designed for larger-scale applications and are compatible with the manu-CART® “10”-II system.

Packing
material

USP Designation

Characteristics/Phase

Pore size (Å)

Particle
size

(µm)

% C 

Endcapped

LiChrospher® 100 RP-18 

L1

Spherical particles of silica with octadecyl derivative

100

5, 10

21.0

no

LiChrospher®RP-18 endcapped

L1

Spherical particles of silica with octadecyl derivative endcapped

100

5, 10

21.6

yes

LiChrospher® PAH

L1

Spherical particles of silica with octadecyl derivative

150

5

proprietary

no

LiChrospher® 100 RP-8 

L7

Spherical particles of silica with octyl derivative

100

5, 10

12.5

no

LiChrospher® 100 RP-8 endcapped

L7

Spherical particles of silica with octyl derivative endcapped

100

5, 10

13.0

yes

LiChrospher® RP-select B

L7

Octylsilane deactivated for the separation

of basic compounds

60

5, 10

11.5

no

LiChrospher® 100 DIOL 

L20

Spherical particles of silica with vicinal hydroxyl function on C-chains

100

5

8.0

no

LiChrospher® 100 NH2  

L8

Spherical particles of silica with aminopropyl function

100

5

4.6

no

LiChrospher® 100 CN

L10

Spherical particles of silica with cyanopropyl function

100

5, 10

6.6

no

LiChrospher® Si 60 

L3

Spherical particles of silica

60

5, 10

n.a.

n.a.

LiChrospher® Si 100

 

Spherical particles of silica

100

5

n.a.

n.a.

LiChrospher® 60 RP-select B

 

Spherical particles of silica with octyl derivative, especially suitable for the RP separation of basic compounds

60

5,10

11.5

no

Table 1.Specifications of LiChrospher® packing materials

LiChrospher® 100 RP-18 and RP-18 endcapped HPLC Columns

LiChrospher® 100 RP-18 and RP-18 endcapped HPLC columns are very reliable and highly versatile C18 phases. These traditionally manufactured spherical silica-based supports are intended for reversed-phase chromatography of acidic, neutral, and weakly basic compounds—substances commonly encountered across various analytical fields. Several individual batches are utilized to create a large master batch of the LiChrospher® RP-18 sorbent. This removes discrepancies among various small batches and guarantees the sorbent's outstanding consistency from one batch to another. As a result, LiChrospher® RP-18 provides consistently reproducible outcomes, ensuring the reliability of your HPLC method.

LiChrospher® RP-18 HPLC Columns are classified as USP L1 columns, meeting the stringent requirements for reversed-phase chromatography and ensuring consistent, high-quality separations in pharmaceutical and analytical applications.

 

LiChrospher® 100 RP-18

LiChrospher® 100 RP-18 endcapped

Sorbent characteristics

Particles of silica with octadecyl derivative

Particles of silica with octadecyl derivative endcapped

Particle shape

Fully porous spherical silica particles (Type A)

Fully porous spherical silica particles (Type A)

Particle size

5, 10 μm

5, 10 μm

Pore size

100 Å (10 nm)

100 Å (10 nm)

Pore volume

1.25 mL/g

1.25 mL/g

Spec. surface area

350 m2/g

350 m2/g

Carbon load

21.0 % C

21.6 % C

Coverage of the surface

4,09 μmol/m2

4.09 μmol/m2

Minimum Efficiency

50,000 N/m (5 µm);
25,000 N/m (10 µm)

55,000 N/m (5 µm);
25,000 N/m (10 µm)

pH range

2-7.5

2-7.5

Shipping eluent

Acetonitrile/water

Acetonitrile/water

LiChrospher® 100 RP-8 and RP-8 endcapped HPLC Columns

LiChrospher® 100 RP-8 and RP-8 endcapped HPLC columns are made from spherical silica gel carriers that exhibit C8 or C8 endcapped reversed-phase characteristics. The columns demonstrate exceptional versatility, making them appropriate for acidic, neutral, and weakly basic compounds. The columns provide excellent selectivity and performance, guaranteeing consistent separations across different batches and over the years.

 

LiChrospher® 100 RP-8

LiChrospher® 100 RP-8 endcapped

Sorbent characteristics

Particles of silica with octyl derivative

Particles of silica with octyl derivative endcapped

Particle shape

Fully porous spherical silica particles (Type A)

Fully porous spherical silica particles (Type A)

Particle size

5, 10 μm

5, 10 μm

Pore size

100 Å (10 nm)

100 Å (10 nm)

Pore volume

1.25 mL/g

1.25 mL/g

Spec. surface area

350 m2/g

350 m2/g

Carbon load

12.5 % C

13 % C

Coverage of the surface

4.04 μmol/m2

4.44 μmol/m2

Minimum Efficiency

55,000 N/m (5 µm);
25,000 N/m (10 µm)

55,000 N/m (5 µm);
25,000 N/m (10 µm)

pH range

2-7.5

2-7.5

Shipping eluent

Acetonitrile/water

Acetonitrile/water

LiChrospher® 60 RP-Select B HPLC Columns

LiChrospher® 60 RP-Select B is designed specifically for HPLC separations of basic compounds. The sorbent, derived from spherical silica particles, effectively prevents secondary interactions with basic substances, ensuring their elution as highly symmetrical peaks. In addition to providing outstanding separation properties for basic compounds, LiChrospher® 60 RP-Select B is also appropriate for the analysis of neutral and acidic substances. For LiChrospher® RP-select B, multiple individual batches are utilized to create a large master batch of the sorbent. This removes discrepancies among various small batches and guarantees the sorbent's outstanding consistency from one batch to another. As a result, LiChrospher® RP-select B column provides exceptionally consistent outcomes, ensuring the dependability of your HPLC method.

The exceptional reproducibility of the “master batch LiChrospher® RP-select B" in comparison to smaller individual batches of the sorbent is clearly evidenced by the Tanaka test, a rigorous HPLC column testing procedure.

Sorbent characteristics

Particles of silica with octyl derivative

Particle shape

Fully porous spherical silica particles (Type A)

Particle size

5 μm

Pore size

60 Å (6 nm)

Pore volume

0.9 mL/g

Spec. surface area

360 m2/g

Carbon load

11.5 % C

Coverage of the surface

3.55 μmol/m2

Minimum Efficiency

55,000 N/m;

pH range

2-7.5

Shipping eluent

Acetonitrile/water

LiChrospher® 100 DIOL HPLC Columns

LiChrospher® 100 DIOL has both polar and hydrophobic characteristics, combining weak hydrophobic interactions with polar interactions. This allows for successful HPLC separation of complex samples. The sorbent can be employed as a less polar alternative to LiChrospher® Si 60 in normal-phase applications, as well as a less hydrophobic alternative (with some limits) to LiChrospher® RP-8 in reversed-phase applications. Furthermore, LiChrospher® DIOL is suitable for HILIC chromatography.

Sorbent characteristics

Particles of silica with diol function on C-chains

Particle shape

Fully porous spherical silica particles (Type A)

Particle size

5 μm

Pore size

100 Å (10 nm)

Pore volume

1.25 mL/g

Spec. surface area

350 m2/g

Carbon load

8.0 % C

Coverage of the surface

3.87 μmol/m2

Minimum Efficiency

40,000 N/m

pH range

2-7.5

Shipping eluent

n-Heptane

LiChrospher® 100 NH2 HPLC Columns

LiChrospher® NH2 is a versatile sorbent that features both polar and hydrophobic characteristics. This makes it appropriate for normal-phase, reversed-phase, HILIC, and ion exchange chromatography. Common applications involve the separation of carbohydrates (mono-, di-, and oligosaccharides) using reversed-phase chromatography, as well as the separation of nucleotides through ion exchange chromatography. 

Sorbent characteristics

Particles of silica with gamma-aminopropyl function

Particle shape

Fully porous spherical silica particles (Type A)

Particle size

5 μm

Pore size

100 Å (10 nm)

Pore volume

1.25 mL/g

Spec. surface area

350 m2/g

Carbon load

4.6 % C

Coverage of the surface

4.1 μmol/m2

Minimum Efficiency

25000 N/m

pH range

2-7.5

Shipping eluent

n-Heptane

LiChrospher® 100 CN HPLC Columns

LiChrospher® 100 CN exhibits a unique combination of polar and hydrophobic properties, integrating weak hydrophobic interactions alongside polar interactions. This facilitates effective HPLC separations of intricate samples. The sorbent is a less polar option than LiChrospher® Si 60 for normal-phase applications or a less hydrophobic choice relative to LiChrospher® RP-8 for reversed-phase applications. This adaptable sorbent is also appropriate for selective charged interactions.

Sorbent characteristics

Particles of silica with gamma-cyanopropyl function

Particle shape

Fully porous spherical silica particles (Type A)

Particle size

5, 10 μm

Pore size

100 Å (10 nm)

Pore volume

1.25 mL/g

Spec. surface area

350 m2/g

Carbon load

6.6 % C

Coverage of the surface

3.52 μmol/m2

Minimum Efficiency

40,000 N/m (5 µm);
15,000 N/m (10 µm)

pH range

2-7.5

Shipping eluent

n-Heptane

LiChrospher® Si 60 and Si 100 HPLC Columns

LiChrospher® Si 60 columns and Si 100 are versatile HPLC columns with superior polar characteristics for normal-phase separations. They use spherical silica particles with pore diameters of 60 or 100 Å and particle sizes of 5 or 10 µm.

 

LiChrospher® Si 60

LiChrospher® Si 100

Sorbent characteristics

Particles of silica

Particles of silica

Particle shape

Fully porous spherical silica particles (Type A)

Fully porous spherical silica particles (Type A)

Particle size

5, 10 μm

5 μm

Pore size

60 Å (10 nm)

100 Å (10 nm)

Pore volume

0.85 mL/g

1.25 mL/g

Spec. surface area

700 m2/g

400 m2/g

Minimum Efficiency

55,000 N/m (5 µm);
20,000 N/m (10 µm)

55,000 N/m

pH range

2-7.5

2-7.5

Shipping eluent

n-Heptane

n-Heptane

LiChrospher® PAH HPLC Columns

LiChrospher® PAH is a highly selective HPLC column, built specifically for the trace analysis of PAH. The column delivers outstanding, high-resolution gradient separations of 16 PAH in accordance with EPA 610 and EPA 550, in addition to benzo[e]pyrene and perylene. Further, the LiChrospher® PAH columns are well-suited for the isocratic separation of 6 PAHs in accordance with the German DIN method. They incorporate programmed fluorescence detection, enabling precise and sensitive analysis. During typical runs, the first eluting polycyclic aromatic hydrocarbon (PAH), naphthalene, appears at approximately 10 minutes, with full separation completed within 30 minutes.

Sorbent characteristics

Particles of silica with octadecyl derivative

Particle shape

Fully porous spherical silica particles (Type A)

Particle size

5 μm

Pore size

150 Å (15 nm)

Spec. surface area

200 m2/g

Carbon load

20 %

pH range

2-7.5

Shipping eluent

Acetonitrile/water

Ordering Information

LiChrospher® HPLC Columns with 5 µm Particle Size in column hardware LiChroCART® Cartridge (manu-CART® required)

Column dimension

 

 

 

 

 

 

 

 

 

 

 

Length (mm)

 

ID (mm)

RP-18 (5 µm)

RP-18 endcapped (5 µm)

PAH (5 µm)

RP-8 (5 µm)

RP-8 endcapped (5 µm)

RP-select B (5 µm)

Diol (5 µm)

CN (5 µm)

NH2 (5 µm)

Si 60 (5 µm)

Si 100 (5 µm)

25

x

4

1.50931.0001*

1.50936.0001*

 

1.50930.0001*

on request

1.50937.0001*

     

55

x

2

 

       

 

 

 

75

x

4

1.50987.0001*

on request

  

on request

1.50993.0001*

 

 

   

100

x

4.6

1.50600.0001

1.50603.0001

 

1.50634.0001

1.50637.0001

1.50640.0001

     

125

x

3

1.50159.0001

 

 

on request

on request

      

125

x

4

1.50823.0001

1.50828.0001

 

1.50822.0001

1.50827.0001

1.50829.0001

1.50826.0001

1.50825.0001

1.50824.0001

1.50820.0001

 

125

x

4

1.50943.0001*

1.50734.0001*

 

1.50942.0001*

on request

1.50981.0001*

     

125

x

4.6

on request

1.51908.0001

 

on request

on request

on request

     

150

x

4.6

1.50601.0001

1.50604.0001

 

1.50635.0001

1.50638.0001

1.50641.0001

     

250

x

3

1.50154.0001

on request

1.50156.0001

on request

on request

1.50155.0001

 

    

250

x

4

1.50833.0001

1.50838.0001

1.50149.0001

 

1.50837.0001

1.50839.0001

1.50836.0001

1.50892.0001

1.50834.0001

1.50830.0001

 

250

x

4

1.50983.0001*

1.50995.0001*

 

1.50982.0001*

on request

1.50984.0001*

     

250

x

4.6

1.50602.0001

  

1.50636.0001

1.50639.0001

  

 

 

 

 

100

x

4.6

1.50600.1003

  

1.50634.1003

 

1.50640.1003

     

125

x

3

1.50159.1003

          

125

x

4

1.50823.1003

  

1.50822.1003

 

1.50981.1003

     

125

x

4.6

 

 

     

 

   

150

x

4.6

     

1.50641.1003

 

 

   

250

x

3

1.50154.1003

    

1.50155.1003

     

250

x

4

1.50833.1003

    

1.50839.1003

     

250

x

4.6

1.50602.1003

  

1.50636.1003

   

 

 

  

4

x

4

1.50957.0001

1.50962.0001

1.50148.0001

1.50956.0001

1.50961.0001

1.50963.0001

1.50960.0001

1.50959.0001

1.50958.0001

1.50955.0001

 

* 3 units

The LiChroCART® columns (75, 100, 125, 150, and 250 mm length) in the list above (2, 3, 4, and 4.6 mm I.D.) require part number 1.51486.0001 manu-CART® cartridge column holder, which can be used to hold one cartridge column with or without a 4-4 mm guard column. LiChroCART® columns 250-10 mm require part number 1.51419.0001 manu-CART® 10. Additional dimensions and validation kits are available as customized packings on request.

LiChrospher® HPLC Columns with 5 µm Particle Size in Hibar® RT column hardware

Column dimension

 

 

 

 

 

 

 

 

 

 

 

Length (mm)

 

ID (mm)

RP-18 (5 µm)

RP-18 endcapped (5 µm)

PAH (5 µm)

RP-8 (5 µm)

RP-8 endcapped (5 µm)

RP-select B (5 µm)

Diol (5 µm)

CN (5 µm)

NH2 (5 µm)

Si 60 (5 µm)

Si 100 (5 µm)

Hibar® RT HPLC Column [1 unit]

50

x

4

 

 

 

 

 

 

 

 

 

 

 

100

x

4.6

1.50545.0001

 

1.50578.0001

1.50581.0001

1.50573.0001

 

 

 

 

125

x

2

on request

1.51907.0001

on request

on request

on request

 

 

 

 

 

125

x

4

1.50477.0001

on request

 

on request

on request

on request

 

 

 

 

 

125

x

4.6

on request

1.51906.0001

on request

on request

on request

 

 

 

 

 

150

x

3

 

 

 

 

 

 

 

 

 

 

 

150

x

4.6

1.50546.0001

1.50549.0001

1.50579.0001

1.50582.0001

1.50574.0001

 

1.51905.0001

 

250

x

3

 

 

 

 

 

 

 

 

 

 

 

250

x

4

1.50377.0001

on request

on request

1.50329.0001

on request

on request

 

 

 

 

1.50316.0001

250

x

4.6

1.50547.0001

1.50550.0001

1.50580.0001

1.50583.0001

1.50575.0001

 

1.51904.0001

 

Validation Kits [3 Hibar® RT HPLC Columns from 3 different sorbent batches]

100

x

4.6

1.50545.1003

 

1.50578.1003

1.50573.1003

 

 

 

 

125

x

4

1.50477.1003

 

 

 

 

 

 

 

 

 

150

x

4.6

 

1.50549.1003

 

 

1.50574.1003

 

 

 

 

250

x

4

1.50377.1003

 

1.50329.1003

 

 

 

 

 

 

240

x

4.6

 

1.50550.1003

 

 

 

 

 

 

 

 

The Hibar® columns are complete with endfittings. When using a guard column with a Hibar® column, we recommend part number 1.51487.0001 guard column cartridge holder for 4-4 mm guard column LiChroCART® cartridges. Additional dimensions are available as customized packings on request.

LiChrospher® HPLC Columns with 10 µm Particle Size in column hardware LiChroCART® Cartridge (manu-CART® required)

Column dimension

 

Length (mm)

 

ID (mm)

RP-18 (10 µm)

RP-18 endcapped (10 µm)

RP-8 (10 µm)

RP-8 endcapped (10 µm)

RP-select B (10 µm)

Diol (10 µm)

CN (10 µm)

NH2 (10 µm)

Si 60 (10 µm)

 

LiChroCART® HPLC Cartridge [1 unit; * 3 units]

10

x

10

 

 

 

 

 

 

 

 

 

 

250

x

4

1.50843.0001

1.50848.0001

1.50842.0001

1.50847.0001

1.50742.0001*

on request

1.50845.0001

 

1.50840.0001

 

250

x

4.6

 

 

 

 

 

 

 

 

 

 

250

 

10

1.50853.0001

1.50858.0001

on request

 

on request

on request

on request

on request

1.50850.0001

 

The LiChroCART® columns (75, 100, 125, 150, and 250 mm length) in the list above (2, 3, 4, and 4.6 mm I.D.) require part number 1.51486.0001 manu-CART® cartridge column holder, which can be used to hold one cartridge column with or without a 4-4 mm guard column. LiChroCART® columns 250-10 mm require part number 1.51419.0001 manu-CART® 10. Additional dimensions and validation kits are available as customized packings on request.

LiChrospher® HPLC Columns with 10 µm Particle Size in Hibar® RT Column Hardware are available on request.

Sign In To Continue

To continue reading please sign in or create an account.

Don't Have An Account?