Skip to Content
Merck
  • Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-17)
Ting Zhou, Qing Cheng, Chengjuan Zou, Ting Zhao, Shan Liu, Marco Pistolozzi, Evina Tan, Ling Xu, Wen Tan
ABSTRACT

In this study, a rapid and sensitive hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry (HILIC-UPLC-MS/MS) method was developed for simultaneous determination of bambuterol and its two major metabolites monocarbamate bambuterol and terbutaline in human plasma. All samples were simply precipitated using acetonitrile and separated on a UPLC-HILIC column under gradient elution with a mobile phase consisting of acetonitrile and water with the addition of 10mm ammonium acetate and 0.1% formic acid at 0.4 mL/min. The analytes were detected by a Xevo TQ-S tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte, and the intra- and inter-day precisions were <12.8%. The analytical runtime within 4.0 min per sample made this method suitable for high throughput determination. The validated method was successfully applied to a clinical pharmacokinetic study of bambuterol in eight healthy volunteers. Furthermore, the effects of the chromatographic conditions on the retention of the analytes on HILIC were investigated, and the benefits of HILIC were evaluated by comparing with a C18 column. The results indicated that liquid-liquid partition and the electrostatic interactions played an important role in the retention of the analytes on HILIC in this study. And HILIC offered particular advantages over RPLC approach in the aspects of the peak symmetry, the column efficiency, and the column pressure.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, NMR reference standard
Neostigmine methyl sulfate, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Bambuterol hydrochloride, >98% (HPLC), powder
Supelco
Sodium carbonate, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
Sodium carbonate, BioUltra, anhydrous, ≥99.5% (calc. on dry substance, T)
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Sodium carbonate, anhydrous, powder, 99.999% trace metals basis
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ammonium acetate solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, BioUltra, for molecular biology, ≥99.0%
Sigma-Aldrich
Sodium carbonate, BioXtra, ≥99.0%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Neostigmine methyl sulfate
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Bambuterol hydrochloride, European Pharmacopoeia (EP) Reference Standard
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium carbonate, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodium carbonate, anhydrous, free-flowing, Redi-Dri, ACS reagent (primary standard), 99.95-100.05% dry basis
Sigma-Aldrich
Sodium carbonate, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Sodium carbonate, ACS reagent, anhydrous, ≥99.5%, powder or granules