콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

123072

Sigma-Aldrich

Luminol

97%

동의어(들):

3-Aminophthalhydrazide, 5-Amino-2,3-dihydro-1,4-phthalazinedione

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C8H7N3O2
CAS Number:
Molecular Weight:
177.16
Beilstein:
383929
EC Number:
MDL number:
UNSPSC 코드:
12352103
PubChem Substance ID:
NACRES:
NA.23

분석

97%

mp

>300 °C (lit.)

SMILES string

Nc1cccc2C(=O)NNC(=O)c12

InChI

1S/C8H7N3O2/c9-5-3-1-2-4-6(5)8(13)11-10-7(4)12/h1-3H,9H2,(H,10,12)(H,11,13)

InChI key

HWYHZTIRURJOHG-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Luminol is a very efficient and commonly used chemiluminiscent compound in condensed phase. When basic solutions of luminol containing oxygen are treated with an oxidizing agent, light is produced. Oxidising agents capable of initiating this particular reaction are Nitrogen dioxide, PAN, hydrogen peroxide, ozone and other atmospheric oxidants.

애플리케이션

  • As a chemiluminiscent substance. Used to measure opsonic and phagocytic function.
  • As a biological sensor. Used to detect the polymorphonuclear leukocytes (PMNL) response in a patient with a myeloperoxidase (MPO) deficiency.
  • Used as a forensic test for blood.
Luminol has been used in a protocol to study the immune-related responses in Arabidopsis thaliana via luminol/peroxidase-based assay.

특징 및 장점

  • Very effective chemiluminiscent compound.
  • Can detect sub-part per billion levels of metal ions with simple and inexpensive instrumentation.
Used for chemiluminescence analysis of, for example, metal cations, blood, and glucococorticoids.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

dust mask type N95 (US), Eyeshields, Gloves


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Fast gas chromatography with luminol chemiluminescence detection for the simultaneous determination of nitrogen dioxide and peroxyacetyl nitrate in the atmosphere
Marley, Nancy A., et al.
The Review of Scientific Instruments, 75, 4595-4605 (2004)
Luminol-based assay for detection of immunity elicitor-induced hydrogen peroxide production in Arabidopsis thaliana leaves.
Bisceglia NG, et al.
Bio-protocol, 5, e1685-e1685 (2015)
T I Quickenden et al.
Luminescence : the journal of biological and chemical luminescence, 16(4), 295-298 (2001-08-21)
A wide range of domestic and industrial substances that might be mistaken for haemoglobin in the forensic luminol test for blood were examined. The substances studied were in the categories of vegetable or fruit pulps and juices; domestic and commercial
Mechanism of cobalt catalysis of luminol chemiluminescence
Burdo, Timothy G., and W. Rudolf Seitz
Analytical Chemistry, 47, 1639-1643 (1975)
C S Easmon et al.
Immunology, 41(1), 67-74 (1980-09-01)
Luminol-dependent chemiluminescence produced by peripheral blood phagocytic cells was measured using a light detecting instrument, the Luminometer 1250 (LKB Wallac). Although less sensitive than liquid scintillation counters, the Luminometer can measure chemiluminescence effectively and detect experimentally induced and clinical variations

문서

Graphene is the building block for carbon nanomaterials with different dimensionalities.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.