콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

34877

Sigma-Aldrich

Water

HPLC Plus, suitable for HPLC, suitable for SM 4500 - NH3

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
H2O
CAS Number:
Molecular Weight:
18.02
Beilstein:
2050024
EC Number:
MDL number:
UNSPSC 코드:
41116105
PubChem Substance ID:
NACRES:
NA.21

product name

Water, HPLC Plus

Grade

HPLC Plus

Agency

suitable for SM 4500 - NH3

vapor density

<1 (vs air)

vapor pressure

3 mmHg

형태

liquid

유통기한

limited shelf life, expiry date on the label

기술

HPLC: suitable

불순물

≤0.0003% non-volatile matter
≤1 ppb fluorescence (quinine) at 254 nm
≤1 ppb fluorescence (quinine) at 365 nm

refractive index

n20/D 1.34 (lit.)

pH

6.0-8.0 (25 °C)

bp

100 °C (lit.)

mp

0 °C (lit.)

density

1.000 g/mL at 3.98 °C (lit.)

음이온 미량물

chloride (Cl-): ≤0.1 mg/kg
fluoride (F-): ≤0.1 mg/kg
nitrate (NO3-): ≤0.1 mg/kg
sulfate (SO42-): ≤0.1 mg/kg

HPLC-gradient

≤1 mAU at 254 nm
≤5 mAU at 210 nm

SMILES string

O

InChI

1S/H2O/h1H2

InChI key

XLYOFNOQVPJJNP-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

HPLC Plus grade water is useful for the UHPLC (Ultra-High Pressure Liquid Chromatography) gradient elution and HPLC studies.

애플리케이션

Water has been used in the following studies:
  • To prepare the diluted hydrochloric acid solutions required for the preparation of standard solutions of amino acid.
  • In the sample extraction step during the gas chromatography mass spectrometric (GC-MS) analysis of free (FAA) and combined amino acids (CAA) in aerosol samples.
  • Preparation of tryptic digests from the standard protein samples and milk digests from milk samples.
  • Preparation of C60-aminopropylsilica.

제조 메모

Product filtered through a 0.2 μm filter

기타 정보

Important notice
  • The article number 34877-4X2.5L will be discontinued. Please order the single bottle 34877-2.5L which is physically identical with the same exact specifications.

추천 제품

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Storage Class Code

12 - Non Combustible Liquids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Manolis Mandalakis et al.
Journal of chromatography. A, 1217(1), 143-150 (2009-12-08)
The analysis of amino acids by gas chromatography mass spectrometry (GC-MS) after their derivatization with N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide was investigated as an alternative approach for the determination of free (FAA) and combined amino acids (CAA) in aerosols. This technique showed excellent linearity
Martin Fischnaller et al.
Analytica chimica acta, 761, 92-101 (2013-01-15)
Phosphorylation of proteins is an important cellular regulatory process. The analysis of protein phosphorylation is challenging due to the high dynamic range and low abundance natures of phosphorylated species. Mass spectrometry (MS) of phosphopeptides obtained from tryptic protein digests is
Rachele M Pojednic et al.
Calcified tissue international, 96(3), 256-263 (2014-12-07)
Vitamin D receptor (VDR) expression and action in non-human skeletal muscle have recently been reported in several studies, yet data on the activity and expression of VDR in human muscle cells are scarce. We conducted a series of studies to
Susu Duan et al.
Nature communications, 5, 5029-5029 (2014-10-10)
Oseltamivir-resistant H1N1 influenza viruses carrying the H275Y neuraminidase mutation predominated worldwide during the 2007-2009 seasons. Although several neuraminidase substitutions were found to be necessary to counteract the adverse effects of H275Y, the order and impact of evolutionary events involved remain
Mary A Rodgers et al.
The Journal of experimental medicine, 211(7), 1333-1347 (2014-06-25)
Linear ubiquitination is a newly discovered posttranslational modification that is currently restricted to a small number of known protein substrates. The linear ubiquitination assembly complex (LUBAC), consisting of HOIL-1L, HOIP, and Sharpin, has been reported to activate NF-κB-mediated transcription in

문서

Ultra-high performance liquid chromatographic (UHPLC) separation of ephedrine and its three structural analogs based on polar retention effect on graphite (PREG) mechanism using Supel™ Carbon LC column.

프로토콜

HPLC Analysis of Purified Adeno-associated Virus (AAV) on TSKgel® SP-NPR

Protocol for HPLC Analysis of Bromelain on TSKgel® BioAssist® S vs. Competitive S Column

Separation of various acids and compounds by molecular weight: PAA, PEI, PIDADMACl, PAS, cationic dextran, chitosan

관련 콘텐츠

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.