1.16892

Supelco

Ammonium Test

reflectometric, 0.2-7.0 mg/L (NH4+), for use with REFLECTOQUANT®

Sign Into View Organizational & Contract Pricing

Synonym(s):
Ammonium chemical test strips, Ammonium test strip for instrument reader

description

quantitative

Quality Level

specific analyte(s)

ammonium

measuring range

0.2-7.0 mg/L (NH4+)

compatibility

RQflex® 10 Plus
RQflex® 10
RQflex® 20
for use with REFLECTOQUANT®

detection method

reflectometric

storage temp.

2-8°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.168991.100241.14752
Ammonium Test reflectometric, 0.2-7.0 mg/L (NH4+), for use with REFLECTOQUANT®

Supelco

1.16892

Ammonium Test

Ammonium Test reflectometric, 5.0-20.0 mg/L (NH4+), for use with REFLECTOQUANT®

Supelco

1.16899

Ammonium Test

Ammonium Test colorimetric, 10-400 mg/L (NH4+), for use with MQuant® StripScan App, MQuant®

Supelco

1.10024

Ammonium Test

Ammonium Test photometric, 0.010-3.00 mg/L (NH4-N), Spectroquant®

Supelco

1.14752

Ammonium Test

compatibility

RQflex® 10 Plus, RQflex® 20, for use with REFLECTOQUANT®

compatibility

RQflex® 10 Plus, RQflex® 20, for use with REFLECTOQUANT®

compatibility

for use with MQuant® StripScan App

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100, for use with Spectroquant® Prove 300, for use with Spectroquant® Prove 600

detection method

reflectometric

detection method

reflectometric

detection method

colorimetric

detection method

photometric (Indophenol blue)

description

quantitative

description

quantitative

description

semi-quantitative

description

-

measuring range

0.2-7.0 mg/L (NH4+)

measuring range

5.0-20.0 mg/L (NH4+)

measuring range

10-400 mg/L (NH4+)

measuring range

0.010-3.00 mg/L (NH4-N), 0.013-3.86 mg/L (NH4+)

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

General description

Method: reflectometric with test strips and reagents 0.2 - 7.0 mg/l NH₄⁺ Reflectoquant®
The Reflectoquant Ammonium test includes test strips and all necessary additional reagents and is suitable for determination potentially harmful pollution in surface and ground water, which are caused by ammonium compounds. Depending on the pH level ammonia is formed, which is a potent toxin for fish. In agriculture the Reflectoquant test strips can be used to measure the ammonium nitrogen content of various types of manure and compost after sample preparation. Ammonium ions react with a chlorinating agent to form monochloramine. This in turn reacts with a phenol compound to form a blue indophenol derivative that is determined reflectometrically on the RQflex. For pre-testing a sample in an economic and quick way to estimate the ammonium concentration and a possible dilution factor prior to using this quantitative method we recommend our semi-quantitative MQuant test strips for ammonium. Further quantitative determination methods can be found with our Spectroquant tests.

Analysis Note

function control: conforms
Assay
- standard 1:
0.4 - 0.6 mg/l
- standard 2: 2.2 - 2.8 mg/l
- standard 3: 5.4 - 6.6 mg/l

Legal Information

REFLECTOQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
RQFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Corrosion

Signal Word

Danger

Storage Class Code

8B - Non-combustible, corrosive hazardous materials


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 10

1 of 10

Ammonium Test colorimetric, 0.5-10 mg/L (NH4+), for use with MQUANT®

Supelco

1.11117

Ammonium Test

Ammonia Assay Kit sufficient for 200 fluorometric tests

Sigma-Aldrich

MAK310

Ammonia Assay Kit

Nitrate Test reflectometric, 5-225 mg/L (NO3-), for use with REFLECTOQUANT®

Supelco

1.16971

Nitrate Test

Ammonium Test colorimetric, 0.2-8 mg/L (NH4+), 0.16-6.2 mg/L (NH4-N), for use with MQUANT®

Supelco

1.14423

Ammonium Test

Ammonium Test colorimetric, 0.2-8.0 mg/L (NH4+), for use with MCOLORTEST®

Supelco

1.14750

Ammonium Test

Recalibration Set

Supelco

1.16954

Recalibration Set

Ammonium Test for use with MQUANT®

Supelco

1.14400

Ammonium Test

Glucose Test reflectometric, 1-100 mg/L (glucose), for use with REFLECTOQUANT®

Supelco

1.16720

Glucose Test

Nitrite Test reflectometric, 0.5-25.0 mg/L (NO2-), for use with REFLECTOQUANT®

Supelco

1.16973

Nitrite Test

Magnesium Test reflectometric, 5-100 mg/L (Mg), for use with REFLECTOQUANT®

Supelco

1.16124

Magnesium Test

Articles

Step-by-step accurate reflectometric determination of ammonium in wastewater with Nessler’s reagent or Indophenol blue using Reflectroquant® system and test strips.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service