MilliporeSigma
All Photos(1)

Documents

SLGNX13TL

Millipore

Millex® Nylon syringe filter

pore size 0.2 μm, diam. 13 mm, non-sterile, hydrophilic

Sign Into View Organizational & Contract Pricing

Synonym(s):
0.2 μm Nylon syringe filter, Millex-GN syringe filter, disposable syringe filter, syringe filter
eCl@ss:
32031690
NACRES:
NB.24

material

Nylon membrane
polypropylene housing

Quality Level

sterility

non-sterile

product line

Millex®

feature

holdup volume≤ 15 μL (after air purge)
hydrophilic

manufacturer/tradename

Millex®

parameter

10 bar max. inlet pressure (150 psi)
18 L/min flow rate
18 mL/min-cm2 water flow rate
45 °C max. temp.

technique(s)

analytical sample preparation: suitable

H

48 mm

diam.

13 mm

filtration area

0.8 cm2

volume

10 mL

pore size

0.2 μm pore size

input

sample type mild organic solution(s)
sample type aqueous solution(s)

bubble point

≥3.0 bar, air with water at 23 °C

fitting

female Luer-Lok® inlet connection
female Luer-Lok® inlet fitting
outlet tube

shipped in

ambient

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
SLGNX13SLHNX13TLSLGN033
Millex® Nylon syringe filter pore size 0.2 μm, diam. 13 mm, non-sterile, hydrophilic

SLGNX13TL

Millex® Nylon syringe filter

Millex® Nylon syringe filter pore size 0.2 μm, diam. 13 mm, non-sterile, hydrophilic

SLGNX13

Millex® Nylon syringe filter

Millex® Nylon syringe filter pore size 0.45 μm, diam. 13 mm, non-sterile, hydrophilic

SLHNX13TL

Millex® Nylon syringe filter

Millex® Nylon syringe filter pore size 0.2 μm, diam. 33 mm, non-sterile, hydrophilic

SLGN033

Millex® Nylon syringe filter

pore size

0.2 μm pore size

pore size

0.2 μm pore size

pore size

0.45 μm pore size

pore size

0.2 μm pore size

manufacturer/tradename

Millex®

manufacturer/tradename

Millex®

manufacturer/tradename

Millex®

manufacturer/tradename

Millex®

diam.

13 mm

diam.

13 mm

diam.

13 mm

diam.

33 mm

fitting

female Luer-Lok® inlet connection, outlet tube, female Luer-Lok® inlet fitting

fitting

female Luer-Lok® inlet connection, female Luer-Lok® inlet fitting, male Luer outlet slip

fitting

female Luer-Lok® inlet connection, female Luer-Lok® inlet fitting, outlet tube

fitting

female Luer-Lok® inlet connection, female Luer-Lok® inlet fitting, male Luer outlet slip

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

General description

Filter Code: GN
Non-Sterile Millex® Syringe Filters with Nylon Membrane:
- Non-sterile Millex syringe filters with hydrophilic nylon membrane are compatible with a broad range of solvents
- Available in 0.20 µm and 0.45 µm pore sizes and two diameters to suit your application needs
- Compatible with both aqueous and organic solutions, providing broad chemical compatibility and flexibility in the lab
- Polypropylene housing, offering a low level of extractables and broad chemical compatibility

Available in Multiple Pack Sizes:
- SKU ending with NS (-------NS): 50 per pack
- SKU ending with NL (-------NL): 100 per pack
- SKU ending with TL (-------TL): 100 per pack. These syringe filters have a tube outlet
- SKU ending with NB (-------NB): 250 per pack
- SKU ending with NK (-------NK): 1000 per pack

Applications:
- Sample Filtration Prior to UHPLC, HPLC, LC-MS, and Mass Spec
- Solvent Filtration
- Clarification of Aqueous and Organic Solutions

Application

0.20 µm pore size, 13 mm diameter, Millex-GN Nylon membrane, hydrophilic, tube outlet

Packaging

non sterile

Specifications

For general laboratory use only

Physical form

Color Code: Purple

Legal Information

Luer-Lok is a registered trademark of Becton-Dickinson & Co.
Millex is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 8

1 of 8

Articles

Filtration is used in dissolution testing to end the dissolution process and prepare the sample for HPLC analysis. This page discusses the importance of filtration and utility of hydrophilic PTFE Millex® syringe filters in dissolution testing.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service