MilliporeSigma
All Photos(1)

57275

Supelco

Visiprep Large Volume Sampler

for use with 3 or 6 mL SPE tubes (includes 4 adapters), suitable for PFAS testing

material

PTFE frit

product line

Visiprep

technique(s)

solid phase extraction (SPE): suitable

application(s)

food and beverages

compatibility

for use with 3 or 6 mL SPE tubes (includes 4 adapters)
technique used for transfers 4 large volume samples

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
5727257273-U57277
technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

application(s)

food and beverages

application(s)

food and beverages

application(s)

food and beverages

application(s)

food and beverages

compatibility

for use with 3 or 6 mL SPE tubes (includes 4 adapters), technique used for transfers 4 large volume samples

compatibility

for use with 12, 20, or 60mL SPE tubes (includes 3 adapters), technique used for transfers 3 large volume samples

compatibility

for use with 3 or 6 mL SPE tubes

compatibility

-

product line

Visiprep

product line

-

product line

-

product line

-

Quality Level

100

Quality Level

100

Quality Level

-

Quality Level

-

General description

For continuous "hands off" direct transfer of multiple liquid samples

A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold.

Two samplers are available. One sampler has three tube adapters compatible with 12mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 12 samples on a 12-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 12 samples, three samplers are required.

The samplers consist of 1/8-inch PTFE tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the PTFE tubing on the samplers are colorcoded for easy sample identification.

Also fits Preppy SPE Vacuum Manifold.

Note: The Visiprep Large Volume Sampler can only be used with polypropylene SPE tubes. You must equip alternate manifold valves with long stem flow control knobs to accommodate 12 mL, 20 mL, or 60 mL SPE tubes.

Application

Visiprep large Volume Sampler was used to extract and determine estrone in water using solid-phase extraction-enzyme-linked immunosorbent assay (SPE-ELISA). It was also used in extraction of polar pesticides from rainwater samples, during extract analysis by LC-MS-MS coupled with electrospray ionization.

Legal Information

Visiprep is a trademark of Sigma-Aldrich Co. LLC

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

R Bossi et al.
Journal of chromatography. A, 957(1), 27-36 (2002-07-10)
A new LC-MS-MS method for analysis of rainwater has been developed and validated for 53 pesticides, degradation products of pesticides and selected nitrophenols. The method was used to monitor the concentration of pesticides in rainwater at one location near Roskilde
Development of a solid-phase extraction-enzyme-linked immunosorbent assay method for the determination of estrone in water.
Li, Zhilan, et al.
Analytica Chimica Acta, 503, 171-177 (2004)

Related Content

PFAS Analysis Solutions | Sigma-Aldrich

Discover our complete solutions: Reliable products and precision tools to more accurately quantify PFAS compounds in diverse samples including water, wastewater, soil, food, blood, etc.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service