MilliporeSigma
  • [Quantitative determination of seven major absorbed volatile constituents in mice brain, liver and blood after intragastric administration of Asari Radix et Rhizoma suspension by headspace-solid phase microextraction-gas chromatography-mass spectrometry].

[Quantitative determination of seven major absorbed volatile constituents in mice brain, liver and blood after intragastric administration of Asari Radix et Rhizoma suspension by headspace-solid phase microextraction-gas chromatography-mass spectrometry].

Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica (2016-01-01)
Zi-Wei Zhang, Guang-Xue Liu, De-Mei Xie, Feng Tian, Yi-Kang Jia, Feng Xu, Ming-Ying Shang, Xuan Wang, Shao-Qing Cai
ABSTRACT

A headspace-solid phase microextraction-gas chromatography-mass spectrometry method(HS-SPME-GC-MS) was adopted for the quantitative study of 4-allylanisole, methyl eugenol, 2,3,5-trimethoxytoluene, 3,4,5-trimethoxytoluene, sarisan, 3,5-dimethoxytoluene and safrole in mice brain, liver tissues and blood after intragastric administration of Asari Radix et Rhizoma. A VF-WAXms (30 m×0.25 mm, 0.25 μm film thickness) capillary column and SPME fiber coated with 65 μm polydimethylsiloxane/divinylbenzene (PDMS/DVB) were used. The calibration curves of seven volatile constituents were established to validate the method's stability (RSD<15%), repeatability (RSD<9.5%), accuracy (RSD<22%), relative recovery (87.0%-108%) and extraction recovery (74.9%-102%). The validated HS-SPME-GC-MS assay was applied to determine the concentrations of seven constituents in liver, brain and blood. The detected contents were 0.22,0.14 μg•g⁻¹,0.25 mg•L⁻¹ (4-allylanisole), 1.1, 0.39 μg•g⁻¹, 0.69 mg•L⁻¹ (methyl eugenol), 0.45, 0.13 μg•g⁻¹, 0.54 mg•L⁻¹ (2,3,5-trimethoxytoluene), 0.51, 0.15 μg•g⁻¹, 0.45 mg•L⁻¹ (3,4,5-trimethoxytoluene), 0.48, 0.039 μg•g⁻¹, 0.69 mg•L ⁻¹ (sarisan), 2.2, 1.2 μg•g⁻¹, 1.5 mg•L⁻¹ (3,5-dimethoxytoluene) and 1.3, 0.67 μg•g⁻¹, 1.1 mg•L⁻¹ (safrole) respectively. This HS-SPME-GC-MS method is rapid and convenient, with a small sample size, and applicable for the analysis and determination of volatile constituents in traditional Chinese medicines, which provides scientific data for further studies on effective substances and toxic substances in Asari Radix et Rhizoma.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), metal alloy fiber, df 100 μm(PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME-OC Fiber Assembly, Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 75 μm(Coating thickness includes 65 μm coating + 10 μm OC (overcoating), needle size 23 ga, pkg of 3 ea, fiber L 1 cm
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME Sampling Stand, for use with 15 mL vials
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler