Skip to Content
MilliporeSigma
  • Simultaneous tissue profiling of eicosanoid and endocannabinoid lipid families in a rat model of osteoarthritis.

Simultaneous tissue profiling of eicosanoid and endocannabinoid lipid families in a rat model of osteoarthritis.

Journal of lipid research (2014-07-27)
Amy Wong, Devi R Sagar, Catharine A Ortori, David A Kendall, Victoria Chapman, David A Barrett
ABSTRACT

We describe a novel LC method for the simultaneous and quantitative profiling of 43 oxylipins including eicosanoids, endocannabinoids, and structurally related bioactive lipids with modified acyl groups. The LC-MS/MS method uses switching at a defined time between negative and positive electrospray ionization modes to achieve optimal detection sensitivity for all the lipids. The validated method is linear over a range of 0.01-5 nmol/g (0.1-50 nmol/g for 2-arachidonoyl glycerol) with intra- and interday precision and accuracy between 1.38 and 26.76% and 85.22 and 114.3%, respectively. The method successfully quantified bioactive lipids in different tissue types in the rat, including spinal cord, dorsal root ganglia (DRGs), knee joint, brain, and plasma. Distinct regional differences in the pattern of lipid measured between tissue types were observed using principle component analysis. The method was applied to analyze tissue samples from an established preclinical rat model of osteoarthritis (OA) pain and showed that levels of 12-hydroxyeicosatetraenoic acid were significantly increased in the OA rat knee joint compared with controls, and that 15-hydroxyeicosatetraenoic acid was significantly increased in the DRGs in the model of OA compared with controls. The developed LC-MS/MS method has the potential to provide detailed pathway profiling in tissues and biofluids where the disruption of bioactive oxylipins may be involved in disease states.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Hexane, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Hexane, suitable for HPLC
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Ethyl acetate, suitable for HPLC
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Ethanol, ≥99.5%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Ethyl acetate, JIS 300, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Ethyl acetate, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for HPLC
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for fluorescence
Sigma-Aldrich
Hexane, ≥96.0%, suitable for residual phthalate analysis
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Ethanol, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Hexane, JIS 1000, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for absorption spectrum analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Ethyl acetate, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Hexane, JIS 300, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Ethyl acetate, SAJ first grade, ≥99.0%
Sigma-Aldrich
Ethanol, ≥99.5%, SAJ super special grade
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Hexane, SAJ first grade, ≥95.0%
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Ethyl acetate, natural, ≥99%, FCC, FG
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles