427772
Polyethylene
average Mw ~4,000 by GPC, average Mn ~1,700 by GPC
Synonym(s):
PE
Sign Into View Organizational & Contract Pricing
All Photos(3)
About This Item
Recommended Products
form
powder
Quality Level
mol wt
average Mn ~1,700 by GPC
average Mw ~4,000 by GPC
viscosity
1.5 poise(25 °C, Brookfield Thermosel)(lit.)
mp
92 °C
acid number
<0.05 mg KOH/g
transition temp
softening point 106 °C (ring and ball)
density
0.92 g/mL at 25 °C
InChI
1S/C2H4/c1-2/h1-2H2
InChI key
VGGSQFUCUMXWEO-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Related Categories
Application
Mold release additive, lubricant in rubber processing, extrusion and calendering aid for PVC and dispersing aid for color concentrates.PEG-4000 may be used as a precipitant during protein fractionation and virus precipitation.Influence of PEG of various molecular weights on mammalian cell hybridization.
Features and Benefits
Low molecular weight and viscosity for easy processing.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
A method for the estimation of polyethylene glycol in plasma protein fractions, Analytical Biochemistry
Analytical Biochemistry, 107(1), 60-63 (1980)
Reduced cortical neurotransmitPolyethylene glycol-induced mammalian cell hybridization: Effect of polyethylene glycol molecular weight and concentration.
Somatic Cell Genetics, 2(3), 271-280 (1976)
Pediatrics, 132(1), e135-e141 (2013-06-19)
Hypothermia on admission to the NICU is associated with increased mortality in preterm infants. Many newborns are hypothermic on admission despite using polyethylene bags (PBs). Using exothermic mattresses (EMs) in addition to PBs may reduce hypothermia but increase hyperthermia. We
Journal of long-term effects of medical implants, 22(2), 177-179 (2013-02-23)
A polyethylene cup explanted after 41 years was examined using several analytical techniques to determine whether there was a material cause for the extremely low wear observed. Neither the amount of polyethylene oxidation nor crystallinity appeared to be a factor.
Rapid communications in mass spectrometry : RCM, 27(6), 713-721 (2013-02-19)
Despite various porous materials having been widely adopted as spraying tips for direct sample analysis using electrospray ionization mass spectrometry (ESI-MS), the effect of surface property and porosity of spraying tip materials on their analytical performances is not clear. Investigation
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service