추천 제품
material
PVDF membrane (hydrophilic)
flat bottom wells
polystyrene
Quality Level
설명
Bead-based assays
무균
non-sterile
제품 라인
MultiScreen®
특징
hydrophilic
lid
제조업체/상표
MultiScreen®
파라미터
50-250 μL sample volume (per well)
기술
activity assay: suitable (protein kinase/phosphatase)
bead-based assay: suitable
여과 면적
0.28 cm2
플레이트 크기
96 wells
웰 최대 용적
300 μL
작업 용적
50-250 μL
기질
Durapore®
공극 크기
1.2 μm pore size
결합 유형
low binding surface
배송 상태
ambient
일반 설명
HTS Filter Plates (Plate catalogue numbers that start with MS)
- MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics.
- Millipore’s new MultiScreen HTS+ Hi flow filter plate design lessens non-specific binding and reduces variability in both background and signal intensities specifically for biochemical screening assays.
Classic Filter Plates (Plate catalogue numbers that start with MA)
- The original multiwell design is valuable for many applications which require immersing the filter in an assay tray. The easily removable underdrain and unique plate design are ideal for assays such as Elispot, PAMPA, cell screening (migration, invasion or chemotaxis) or for topcount detection users.
Accessory – MultiScreenHTS Vacuum Manifold
- The MultiScreenHTS Vacuum manifold was designed specifically to work with MultiScreenHTS filter plates. The combination results in optimal filtration characteristics and seamless automation integration.
Millicell Assay Plates
- In addition to the traditional assay plate format, filter plates are also available with cell culture trays for growing and assaying suspension and adherent cell lines. Cells grown on filter plates differentiate better than those grown on traditional plastic substrates, resulting in more in vivo-like results This filter plate/tray combination can be used for a variety of cellular assays, including, transport, toxicity and screening assays.
애플리케이션
Bead/Resin based assays
General Filtration
Protein
물리적 형태
기타 정보
법적 정보
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
Storage Class Code
10-13 - German Storage Class 10 to 13
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
프로토콜
Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.
관련 콘텐츠
여과법은 물리적 또는 화학적 특성에 따라 물질을 분리합니다. 실험실 시료는 사료의 복잡성을 줄이고 분석물의 순도를 높이기 위해 분석 전에 일반적으로 여과합니다. 이를 통해 과학자들은 고품질의 분석 결과를 얻을 수 있습니다.
Filtration separates substances to reduce sample complexity and increase analyte purity, improving analytical results.
This provides information about the chemical compatibility of MultiScreen Filter Plates with different reagents.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.