Skip to Content
MilliporeSigma
All Photos(1)

Documents

D-062

Supelco

21-Deoxycortisol solution

100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Sign Into View Organizational & Contract Pricing

Empirical Formula (Hill Notation):
C21H30O4
CAS Number:
Molecular Weight:
346.46
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material

Quality Level

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

100 μg/mL in methanol

technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

application(s)

clinical testing
clinical testing

format

single component solution

storage temp.

−20°C

SMILES string

CC(=O)C1(O)CCC2C3CCC4=CC(=O)CCC4(C)C3C(O)CC12C

InChI

1S/C21H30O4/c1-12(22)21(25)9-7-16-15-5-4-13-10-14(23)6-8-19(13,2)18(15)17(24)11-20(16,21)3/h10,15-18,24-25H,4-9,11H2,1-3H3/t15-,16-,17-,18+,19-,20-,21-/m0/s1

InChI key

LCZBQMKVFQNSJR-UJPCIWJBSA-N

General description

A new calibration material suitable for LC/MS applications in clinical and diagnostic testing and endocrinology. 21-deoxycortisol, a steroid intermediate in the formation of cortisol, is measured in whole blood or serum by LC/MS for newborn screening of congenital adrenal hyperplasia (CAH) and other adrenal diseases.

Application

  • Steroid profiling for the diagnosis of congenital adrenal hyperplasia by microbore ultra-performance liquid chromatography-tandem mass spectrometry: This article emphasizes the significance of steroid profiling using advanced chromatography techniques to diagnose congenital adrenal hyperplasia, highlighting the role of 21-Deoxycortisol as a critical marker (Feng D et al., 2023).
  • Second-tier Testing for 21-Hydroxylase Deficiency in the Netherlands: A Newborn Screening Pilot Study: This study introduces a second-tier testing protocol involving 21-Deoxycortisol to enhance the screening process for congenital adrenal hyperplasia in newborns, demonstrating its utility in early and accurate diagnosis (Stroek K et al., 2021).

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes

wgk_germany

WGK 1

flash_point_f

closed cup

flash_point_c

closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Diagnosing Cushing's syndrome.
A A Ismail et al.
Annals of clinical biochemistry, 35 ( Pt 2), 324-325 (1998-04-21)
K Müssig et al.
Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association, 114(4), 208-214 (2006-05-18)
Congenital adrenal hyperplasia results from 21-hydroxylase deficiency in more than ninety percent of cases. The classical form of 21-hydroxylase deficiency presents in the neonatal period with virilization or adrenal insufficiency, with or without concurrent salt wasting. We report on a
A Milewicz et al.
Endokrynologia Polska, 44(2), 187-193 (1993-01-01)
The study was aimed at evaluation of usefulness of determination of blood serum 21-deoxycortisol concentration for the detection of heterozygous carriers of incomplete block of 21-hydroxylase synthesis leading to adrenal hyperplasia. An earlier observation of the authors that the determination
M Hill et al.
Steroids, 60(9), 615-620 (1995-09-01)
A radioimmunoassay of three deoxycorticoids, namely 11 beta,17 alpha-dihydroxy-4-pregnene-3,20-dione (21-deoxycortisol), 17 alpha,21-dihydroxy-4-pregnene-3,20-dione (11-deoxycortisol), and 21-hydroxy-4-pregnene-3,20-dione (11-deoxycorticosterone) which are important for differential diagnosis of congenital adrenal disorders, is described and evaluated. Antisera against 3-(O-carboxymethyl)oximes conjugated to bovine serum albumin were raised
J Fiet et al.
Annals of clinical biochemistry, 31 ( Pt 1), 56-64 (1994-01-01)
21-deoxycortisol (21-DF) is a steroid of strictly adrenal origin formed by the 11-hydroxylation of 17-hydroxyprogesterone. This metabolic pathway is minor in normal subjects, in whom basal plasma concentrations range from 0.03 to 0.63 nmol/L and from 0.865 to 1.50 nmol/L

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service