MilliporeSigma
All Photos(1)

T-074

Supelco

3,3′,5-Triiodo-L-thyronine (T3) solution

100 μg/mL in methanol with 0.1N NH3, ampule of 1 mL, certified reference material, Cerilliant®

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
3,3′,5-Triiodo-L-thyronine, O-(4-Hydroxy-3-iodophenyl)-3,5-diiodo-L-tyrosine, Liothyronine, T3
Empirical Formula (Hill Notation):
C15H12I3NO4
CAS Number:
Molecular Weight:
650.97
Beilstein:
2710227
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

100 μg/mL in methanol with 0.1N NH3

technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

mp

234-238 °C (lit.)

application(s)

clinical testing
clinical testing

format

single component solution

storage temp.

−20°C

SMILES string

N[C@@H](Cc1cc(I)c(Oc2ccc(O)c(I)c2)c(I)c1)C(O)=O

InChI

1S/C15H12I3NO4/c16-9-6-8(1-2-13(9)20)23-14-10(17)3-7(4-11(14)18)5-12(19)15(21)22/h1-4,6,12,20H,5,19H2,(H,21,22)/t12-/m0/s1

InChI key

AUYYCJSJGJYCDS-LBPRGKRZSA-N

Gene Information

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
T2877PHR1504T-077
Liothyronine Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1504

Liothyronine

form

liquid

form

powder

form

solid

form

liquid

packaging

ampule of 1 mL

packaging

-

packaging

pkg of 500 mg

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

manufacturer/tradename

-

manufacturer/tradename

-

manufacturer/tradename

Cerilliant®

concentration

100 μg/mL in methanol with 0.1N NH3

concentration

-

concentration

-

concentration

100 μg/mL in methanol with 0.1N NH3

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

technique(s)

transfection: suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

General description

This Certified Spiking Solution® is suitable for use as a starting material in the preparation of linearity standards, calibrators, and controls for thyroid hormone testing methods by LC-MS/MS.

3,3′,5-Triiodo-L-thyronine (T3) is a thyroid hormone and active form of L-thyroxine (T4), formed by deiodinase type I or II. It supports various physiological functions, such as oxygen consumption, carbohydrate metabolism, protein synthesis, and neural development. Free and total T3 serum levels are measured by LC-MS/MS for the determination of hyperthyroidism caused by excess T3.

Application

The Certified Reference Material (CRM) in solution can also be used as follows:

  • Multi-residue determination of seven thyroid hormones in placenta samples by isotope dilution liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS)
  • Parts-per-trillion analysis of five thyroid hormones in zebrafish larvae by their solid phase extraction (SPE) and ultra-high performance liquid chromatography-electrospray ionization- tandem mass spectrometric (UPLC-ESI/MS/MS) analysis
  • Simultaneous analysis of six free thyroid hormones in bovine serum samples by ultrafiltration and high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS)
  • Determination of six thyroid hormones in mouse tissue samples by isotope dilution nano-ultraperformance liquid chromatography–quadrupole time-of-flight mass spectrometry (Q-TOF-MS)
  • Identification and quantification of triiodothyronine and thyroxine in rat serum samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Features and Benefits

  • Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
  • Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
  • Flame sealed under argon into ampoules for long-term shelf life
  • Offered in a convenient, DEA-exempt format to improve laboratory efficiency

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTIONS is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

49.5 °F - closed cup

Flash Point(C)

9.7 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 4

1 of 4

L-Thyroxine ≥98% (HPLC)

Sigma-Aldrich

T2376

L-Thyroxine

Liothyronine United States Pharmacopeia (USP) Reference Standard

USP

1368008

Liothyronine

L-Thyroxine powder, BioReagent, suitable for cell culture

Sigma-Aldrich

T1775

L-Thyroxine

Vasiliki Michopoulos et al.
Fertility and sterility, 99(7), 2084-2091 (2013-03-20)
To determine whether cognitive behavior therapy (CBT), which we had shown in a previous study to restore ovarian function in women with functional hypothalamic amenorrhea (FHA), could also ameliorate hypercortisolemia and improve other neuroendocrine and metabolic concomitants of in FHA.
V N Buriak et al.
Likars'ka sprava, (5)(5), 58-63 (2013-03-29)
The paper deals with etiopathogenetic and clinical peculiarities, and also therapeutic methods during the pathological processes in the thyroid system in the childhood. The most common of these processes is the diffuse nontoxic goiter, which results in abnormality of metabolic
Min Kyong Moon et al.
European journal of endocrinology, 168(6), 805-810 (2013-03-21)
Body adiposity, especially ectopic fat accumulation, has a range of metabolic and cardiovascular effects. This study aimed to investigate whether thyroid function is associated with various regional fat quantities in euthyroid subjects. A total of 100 euthyroid men (free triiodothyronine
Min Wang et al.
Neuro endocrinology letters, 34(1), 62-70 (2013-03-26)
To evaluate the poly(dextrogyr-levogyr) lactide acid-triiodothyronine (PDLLA-T3) seeded with Schwann cells conduit for repairing sciatic nerve defect. The rats were divided into three groups: autologous nerve transplantation (Group A), PDLLA-T3 + Schwann cells (Group B) and PDLLA + Schwann cells
R Gärtner
Deutsche medizinische Wochenschrift (1946), 138(27), 1413-1420 (2013-06-27)
The autoimmune thyroiditis with overt or subclinical primary hypothyroidism is the most common endocrine disease. Although the diagnosis of hypothyroidism is not difficult, the question when a replacement therapy in subclinical hypothyroidism should be initiated is still under discussion. In

Protocols

Online SPE/LC-MS Method for the Rapid Analysis of Thyroid Hormones in Plasma

Determination of the thyroid hormones T4, T3 and rT3 from plasma using an Ascentis Express RP-Amide cartridge to trap the analytes, and a Phenyl-Hexyl column to resolve them.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service