추천 제품
Grade
for ion-selective electrodes
Quality Level
제품 라인
Selectophore™
분석
≥95%
형태
powder
SMILES string
CCCCCCCCCCCCCCCCCCNC(=O)COCC(=O)N1CCOCCOCCOCCN(CCOCCOCC1)C(=O)COCC(=O)NCCCCCCCCCCCCCCCCCC
InChI
1S/C58H112N4O11/c1-3-5-7-9-11-13-15-17-19-21-23-25-27-29-31-33-35-59-55(63)51-72-53-57(65)61-37-41-67-45-46-68-42-38-62(40-44-70-48-50-71-49-47-69-43-39-61)58(66)54-73-52-56(64)60-36-34-32-30-28-26-24-22-20-18-16-14-12-10-8-6-4-2/h3-54H2,1-2H3,(H,59,63)(H,60,64)
InChI key
LKKJODPUVIMZGC-UHFFFAOYSA-N
일반 설명
Visit our Sensor Applications portal to learn more.
애플리케이션
Selected application examples
Calcium ionophore V (K23E1) may be used in fabricating calcium on to the waveguide sensor to understand the selectivity of the specific ion and also measure its concentration.
포장
Bottomless glass bottle. Contents are inside inserted fused cone.
기타 정보
Employed in highly calcium-selective membrane electrodes exhibit excellent selectivity toward alkali and earth alkali ions (log KPOT(Ca2+,Mg2+ = -5.0)) and extremely high lipophilicity (log PTLC ionophore: 14.6); Neutral ionophore used in a calcium-selective optode
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
관련 제품
제품 번호
설명
가격
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
Flow-through type calcium ion selective optodes based on novel neutral ionophores and a lipophilic anionic dye
Analytica Chimica Acta, 299, 179-179 (1994)
Design and Synthesis of Calcium and Magnesium Ionophores Based on Double-Armed Diazacrown Ether Compounds and Their Application to an Ion-Sensing Component for an Ion-Selective Electrode
Analytical Chemistry, 67, 324-324 (1995)
PloS one, 6(5), e20245-e20245 (2011-06-03)
Immune adaptation is a critical component of successful pregnancy. Of primary importance is the modification of cytokine production upon immune activation. With the discovery that normal pregnancy itself is a pro-inflammatory state, it was recognised that the classical Th1/Th2 cytokine
Active optical thin-film waveguide sensor for ion sensing
Analytica Chimica Acta, 343, 199-199 (1997)
Journal of allergy, 2012, 580873-580873 (2011-12-22)
Background. An in vitro basophil activation test, based on the detection of CD63 upregulation induced by NSAIDs, has been described. Its clinical significance remains controversial. Objectives. In patients with a history of nonallergic NSAID hypersensitivity, stratified according to the severity
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.