콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

46385

Supelco

Florisil® Inorganic Adsorbent

60-100 mesh

동의어(들):

Florisil®, Activated magnesium silicate, Magnesium silicate

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
MgO3Si
CAS Number:
Molecular Weight:
100.39
EC Number:
MDL number:
UNSPSC 코드:
23201100
PubChem Substance ID:
NACRES:
SB.52

product name

Florisil® Adsorbent for Chromatography, 60-100 mesh

Grade

standard

Quality Level

형태

coarse powder

기술

LPLC: suitable

기질

Magnesium silicate hydrate

기질 활성군

magnesium silicate hydrate

입자 크기

149-250 μm
60-100 mesh

공극 크기

60 Å mean pore size

분리 기술

hydrophilic interaction (HILIC)

SMILES string

[Mg++].[O-][Si]([O-])=O

InChI

1S/Mg.O3Si/c;1-4(2)3/q+2;-2

InChI key

FKHIFSZMMVMEQY-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Florisil, adsorbent for the separation of lipids, is a commercially-prepared magnesia silica gel. It has a coarse mesh size which helps in rapid flow rate. Florisil is effective in promoting [1,3]-sigmatropic shift of myceophenolic acid related allyl phenyl ethers. Florisil cartridges are used in atmospheric sampling to assess possible interference from air contaminants.

애플리케이션

Florisil was used:
  • as column packing material in column chromatography
  • as an adsorbent in gas chromatography with electron capture detector (GC/ECD), capillary column chromatography, adsorption column chromatography
  • in clean-up procedures in gas chromatography-tandem mass spectrometry and GC-FID

주의사항

may contain some dark particles

법적 정보

Florisil is a registered trademark of U.S. Silica Company

Storage Class Code

13 - Non Combustible Solids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

An improved gas chromatographic method for the determination of perfluorocarbon tracers in the atmosphere
Lagomarsino, Raymond J.
Journal of Chromatography A, 34, 405-412 (1996)
Andrew C Singer et al.
Environmental toxicology and chemistry, 22(9), 1998-2004 (2003-09-10)
This study investigated the interactive effects of bioaugmentation, biostimulation, and the rhizosphere during remediation of Aroclor 1242-contaminated soil. Treatments were repeatedly augmented with polychlorinated bipheny (PCB)-degrading bacteria, inducers (carvone and salicylic acid), surfactant (sorbitan trioleate), minimal salts medium in a
Determination of atmospheric perfluorocarbon background concentrations of fL/L range at the western coastal area of Korea
Kim, HyeKyeong, et al.
Atmospheric Environment, 1, 4-4 (2002)
R C Prados-Rosales et al.
Journal of chromatography. A, 993(1-2), 121-129 (2003-05-09)
A rapid analytical method for determination of organochlorine pesticide residues in sunflower seeds based on focused microwave-assisted Soxhlet extraction has been developed. The main factors affecting the extraction efficiency--namely microwave power, irradiation time, volume of extractant and number of cycles--were
The Florisil? catalyzed [1, 3]-sigmatropic shift of allyl phenyl ethers-An entryway into novel mycophenolic acid analogues.
Talamas, Francisco X., et al.
Tetrahedron Letters, 38, 4725-4728 (1997)

관련 콘텐츠

저압 액체 크로마토그래피(LPLC)는 고정상이 들어있는 컬럼에서 펌프 작동으로 이동상을 이동시키기 위해 저압으로 작동하는 크로마토그래피 기술입니다.

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.