추천 제품
material
fused silica
Quality Level
Agency
meets requirements for USP G5
파라미터
≤25-250 °C temperature (isothermal or programmed)
베타 값
313
df
0.20 μm
기술
gas chromatography (GC): suitable
길이 × I.D.
30 m × 0.25 mm
기질 활성군
Non-bonded; poly(biscyanopropyl siloxane) phase
컬럼 유형
capillary highly polar
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Application: This non-bonded column offers the highest polarity in its class. As with all general purpose biscyanopropyl columns, it is highly effective for both high and low temperature separations of geometric isomers of fatty acid methyl esters (FAMEs), dioxins, carbohydrates, and aromatic compounds.
USP Code: This column meets USP G5 requirements.
Phase:
USP Code: This column meets USP G5 requirements.
Phase:
- Non-bonded
- Poly(biscyanopropyl siloxane)
- Subambient to 250 °C (isothermal or programmed)
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column. SP®-2340 is a cyanopropylsiloxane stationary phase, and has high polarity and temperature resistance.
애플리케이션
Capillary column coated with SP®-2340 stationary phase may be used in gas chromatographic analysis and separation of cis/trans isomeric fatty acids.
기타 정보
We offer a variety of chromatography accessories including analytical syringes
법적 정보
SP is a registered trademark of Sigma-Aldrich Co. LLC
SP 2340 in the glass capillary chromatography of fatty acid methyl esters.
Heckers HF
Journal of Chromatography A, 136 (2), 311-317 (1977)
H Heckers et al.
The American journal of clinical nutrition, 31(6), 1041-1049 (1978-06-01)
Fatty acid patterns were determined in 83 brands of margarine, 9 brands of low-calorie margarine and 18 brands of shortening, frying and cooking fat purchased at random from the retail marker in the Federal Republic of Germany in 1973/1974, and
T Iida et al.
Journal of lipid research, 24(2), 211-215 (1983-02-01)
Capillary gas-liquid chromatographic separation was studied for the complete set of the 26 theoretically possible isomers of mono-, di-, and trihydroxylated 5 beta-cholanic acids, which differ from one another in the number, position, and configuration of hydroxyl groups at C-3
H Heckers et al.
Atherosclerosis, 28(4), 389-398 (1977-12-01)
With the aid of a highly selective capillary column coated with SP 2340, individual trans-fatty acids were identified in all tissue samples studied, the values being unrelated to the degree of atherosclerosis. The mean values of total trans-acids present in
C F Poole et al.
Journal of chromatography. A, 912(1), 107-117 (2001-04-20)
The solvation parameter model is used to study the influence of temperature and composition on the selectivity of nine poly(siloxane) and two poly(ethylene glycol) stationary phase chemistries for open-tubular column gas chromatography. A database of system constants for the temperature
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..