Skip to Content
MilliporeSigma
  • Microextraction of non-steroidal anti-inflammatory drugs from waste water samples by rotating-disk sorptive extraction.

Microextraction of non-steroidal anti-inflammatory drugs from waste water samples by rotating-disk sorptive extraction.

Talanta (2014-07-26)
Valentina Manzo, Luis Honda, Orielle Navarro, Loreto Ascar, Pablo Richter
ABSTRACT

In this study, six non-steroidal anti-inflammatory drugs (NSAIDs) were extracted from water samples using the rotating-disk sorptive extraction (RDSE) technique. The extraction disk device contains a central cavity that allows for the incorporation of a powdered sorbent phase (Oasis™ HLB). The analytes were extracted from water and pre-concentrated on the sorbent to reach the extraction equilibrium, and then they were desorbed with solvent, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). The variables for the extraction were studied using high performance liquid chromatography with a diode array detector (HPLC-DAD) to avoid the derivatization step, and the optimum values were as follows: 60 mg of Oasis™ HLB, a rotation velocity of 3,000 rpm, a pH of 2, a sample volume of 50 mL, and an extraction time of approximately 90-100 min. The recoveries ranged from 71 to 104%, with relative standard deviations (RSD) between 2 and 8%. The detection limits ranged from 0.001 to 0.033 µg L(-1). The described method was applied to the analysis of influents and effluents from wastewater treatment plants (WWTP) in Santiago, Chile. The concentrations of the detected drugs ranged from 1.5 to 13.4 µg L(-1) and from 1.0 to 3.2 µg L(-1) in the influents and effluents, respectively. The samples were extracted by solid phase extraction (SPE). No significant differences were observed in the determined concentrations for most of the NSAIDs, indicating that RDSE is an alternative method for the preparation of water samples.

MATERIALS
Product Number
Brand
Product Description

Supelco
Sodium hydroxide concentrate, 0.1 M NaOH in water (0.1N), Eluent concentrate for IC
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Acetone, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Acetone, suitable for chromatography, ≥99.8%
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Sodium chloride solution, 1 M
Sigma-Aldrich
Acetone, suitable for residue analysis, ≥99.5%
Sigma-Aldrich
Sodium chloride, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetone, SAJ first grade, ≥99.0%
Sigma-Aldrich
Sodium hydroxide solution, 0.1 M
Sigma-Aldrich
Sodium chloride solution, 0.1 M
Sigma-Aldrich
Sodium hydroxide solution, 7 M
Sigma-Aldrich
Sodium hydroxide solution, 4 M
Sigma-Aldrich
Acetone, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetone, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Sodium hydroxide solution, 6 M
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, suitable for residue analysis
Supelco
Ibuprofen
Sigma-Aldrich
Methanol, suitable for HPLC
Sigma-Aldrich
Sodium hydroxide solution, 1 M
Sigma-Aldrich
Sodium hydroxide solution, 0.05 M
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Sodium chloride, JIS special grade, ≥99.5%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Sodium chloride, random crystals, 99.9% trace metals basis
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Acetone, ≥99%, meets FCC analytical specifications