おすすめの製品
物質
fused silica
品質水準
認証
meets requirements for USP G27 and G36
パラメーター
-60-320 °C temperature (isothermal or programmed)
β値
63
df
1.00 μm
テクニック
gas chromatography (GC): suitable
L × 内径
60 m × 0.25 mm
マトリックス活性基
Bonded; poly(5% diphenyl/95% dimethyl siloxane) phase
カラムタイプ
capillary non-polar
類似した製品をお探しですか? 訪問 製品比較ガイド
詳細
用途:この非極性汎用カラムは、特に芳香族化合物に対する選択性がわずかに増加した沸点溶出順序を有しています。
USPコード:このカラムは、USP G27およびG36の要件を満たしています。
相:
USPコード:このカラムは、USP G27およびG36の要件を満たしています。
相:
- 結合済み
- ポリ(5%ジフェニル/95%ジメチルシロキサン)
- ≤内径0.32 mm、<2 μm:-60°C~320°C(等温またはプログラム温度)
- 内径≤0.32 mm、≥2 μm:-60°C~300°C(等温またはプログラム温度)
- 内径≥0.53 mm、<2 μm:-60°C~300°C(等温)または320°C(プログラム温度)
- 内径≥0.53 mm、≥2 μm:-60°C~260°C(等温)または280°C(プログラム温度)
アプリケーション
SPB®-5 Capillary GC Column was used for speciation of the nitrogen compounds (quantitatively), which are polar and somewhat basic in nature, with chemiluminescence detection. It may also be used as stationary phase for determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography. Furthermore, it may also find application in being used as stationary phase in capillary column gas chromatography for determination of sterols.
その他情報
We offer a variety of chromatography accessories including analytical syringes
法的情報
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
24037:
Determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography.
Journal - Association of Official Analytical Chemists, 69 (5), 889-893 (1985)
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
Veterinarni medicina, 37(8), 471-478 (1992-08-01)
Occurrence of individual polychlorinated biphenyl (PCB) congeners in the environment, foodstuffs and other biological materials was assessed. Analysis of specific PCB congeners (28, 52, 101, 138, 153, 180), occurring in animal raw materials and foodstuffs most frequently, has been implemented.
Forensic science international, 46(3), 169-180 (1990-07-01)
Positive-ion electron impact (PIEI), positive-ion chemical ionization (PICI) and negative-ion chemical ionization (NICI) mass spectra of 9 carbamate pesticides are presented. In the PIEI mode, the spectra showed small molecular peaks, intense or base peaks due to M - CH3NHCO
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.