콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

223867

Sigma-Aldrich

Tolylene-2,6-diisocyanate

97%

동의어(들):

2-Methyl-m-phenylene diisocyanate

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH3C6H3(NCO)2
CAS Number:
Molecular Weight:
174.16
Beilstein:
2211546
EC Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

Quality Level

분석

97%

형태

liquid

autoignition temp.

>1148 °F

refractive index

n20/D 1.571 (lit.)

bp

129-133 °C/18 mmHg (lit.)

density

1.225 g/mL at 25 °C (lit.)

저장 온도

2-8°C

SMILES string

Cc1c(cccc1N=C=O)N=C=O

InChI

1S/C9H6N2O2/c1-7-8(10-5-12)3-2-4-9(7)11-6-13/h2-4H,1H3

InChI key

RUELTTOHQODFPA-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

픽토그램

Skull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 2 Inhalation - Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 2

Flash Point (°F)

230.0 °F - closed cup

Flash Point (°C)

110 °C - closed cup

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

P Carbonnelle et al.
The Analyst, 121(5), 663-669 (1996-05-01)
In recent years, epidemiological evidence that exposure to toluene diisocyanate (TDI) is associated with adverse health effects has led to the development of useful analytical methods for the biological monitoring of TDI. In this paper, an HPLC method is presented
G Sesana et al.
American Industrial Hygiene Association journal, 52(5), 183-186 (1991-05-01)
A new sampling system is presented that uses solid sorbent media contained in a tube for the determination of airborne isocyanates (2.4-2.6 toluene diisocyanate, hexamethylene diisocyanate, and 4.4' diaminodiphenylmethane diisocyanate). The method is compared with the National Institute for Occupational
Sébastien Gagné et al.
The Analyst, 128(12), 1447-1451 (2004-01-23)
Isocyanates can cause occupational asthma. By using available HPLC-UVF methods, isocyanates can be quantified only at levels above 1% of the Permissible Exposure Limits (PEL). Once sensitized, workers can react to concentrations below these limits of detection (LOD) making these
S Mattoli et al.
The American journal of physiology, 259(4 Pt 1), L320-L327 (1990-10-01)
Bronchial epithelial cells release chemotactic factors for lymphocytes and express HLA-DR antigens. Thus they may contribute to the T-cell-mediated inflammatory responses involved in a number of pulmonary diseases such as asthma. In this study, the in vitro exposure of human
P Maestrelli et al.
Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology, 24(1), 29-34 (1994-01-01)
To assess the nature and the time-course of the cellular component of airway inflammation induced by isocyanates, we examined nine subjects with occupational asthma induced by toluene- or methylene diphenyl-diisocyanate (TDI, MDI) and four control subjects never exposed to isocyanates.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.