추천 제품
Quality Level
분석
97%
refractive index
n20/D 1.4204 (lit.)
bp
228-229 °C (lit.)
density
0.793 g/mL at 25 °C (lit.)
SMILES string
CCCCCCOCCCCCC
InChI
1S/C12H26O/c1-3-5-7-9-11-13-12-10-8-6-4-2/h3-12H2,1-2H3
InChI key
BPIUIOXAFBGMNB-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Dihexyl ether has been used as:
- supported liquid membrane during hollow-fiber liquid-phase microextraction method for determination of nitrophenolic compounds from atmospheric aerosol particles
- an extraction solvent to detect avermectins in stream water by hollow-fiber-assisted liquid-phase microextraction technique coupled with LC-MS/MS
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 2 - Skin Sens. 1B
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
172.4 °F - closed cup
Flash Point (°C)
78 °C - closed cup
개인 보호 장비
Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)
이미 열람한 고객
Peyman Moradi et al.
Journal of separation science, 42(4), 897-905 (2018-12-18)
A simple method is introduced providing a highly clean microextraction for the determination of some anti-inflammatory drugs as the model analytes in human urine and environmental matrices. This method is based upon the implementation of two consecutive emulsification liquid-phase microextractions
Ali Reza Fakhari et al.
Electrophoresis, 36(24), 3034-3041 (2015-09-19)
In this paper, for the first time, surfactant-assisted electromembrane extraction coupled with capillary electrophoresis with UV detector was introduced for the extraction of acidic drugs from biological fluids. In this technique, in the presence of the nonionic surfactant in the
Cristina Román-Hidalgo et al.
Talanta, 199, 290-295 (2019-04-07)
A chitosan membrane composed by 60% (w/w) chitosan and 40% (w/w) Aliquat®336 has been proposed as a new biopolymeric support for electromembrane extraction. The new support has been characterized by Scanning Electron Microscopy, resulting a 30-35 µm thickness. Amoxicillin, nicotinic acid
Jong-Hyouk Park et al.
Journal of separation science, 36(17), 2946-2951 (2013-03-19)
In this study, a hollow-fiber-assisted liquid-phase microextraction (HF-LPME) technique coupled with LC-MS/MS is described to detect avermectins (abamectin, ivermectin, moxidectin, and doramectin) in stream water. An Accurel polypropylene membrane was used as the hollow fiber, and dihexyl ether was used
María Ramos-Payan et al.
Talanta, 165, 496-501 (2017-02-06)
A fast double-flow microfluidic based liquid phase microextraction (DF-µLPME) combined with a HPLC-UV procedure using diode array detection has been developed for the determination of the four most widely used parabens: Ethyl 4-hydroxybenzoate (EtP), Propyl 4-hydroxybenzoate (PrP), Butyl 4-hydroxybenzoate (BuP)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.