추천 제품
Quality Level
양식
beads
용융 지수
4 g/10 min (230°C/2.16kg)
분자량
average Mn ~97,000
average Mw ~340,000
경도
99 (Rockwell R, ASTM D 785-A)
전이 온도
Tm 160-165 °C
density
0.9 g/mL at 25 °C (lit.)
응용 분야
battery manufacturing
SMILES string
CC=C
InChI
1S/C22H42O3/c1-2-3-4-5-11-14-17-20-21(25-20)18-15-12-9-7-6-8-10-13-16-19-22(23)24/h20-21H,2-19H2,1H3,(H,23,24)/t20-,21+/m1/s1
InChI key
NSYDMBURIUSUDH-RTWAWAEBSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Used with ram- and screw-injection machines. For automotive, housewares, general molding products and multi- and monofiliment fiber.
특징 및 장점
High stiffness and resistance to solvents and chemicals. Resistant to environmental stress cracking. More prone to oxidation than polyethylene.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association, 135, 111010-111010 (2019-12-04)
Current analyses show a widespread occurrence of microplastic particles in food products and raise the question of potential risks to human health. Plastic particles are widely considered to be inert due to their low chemical reactivity and therefore supposed to
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V, 47(3), 283-287 (1999-06-26)
The possibility to control the release rate of salbutamol through the hydrophobic Celgard 2500 polypropylene membrane by varying the composition and the viscosity of hydrophilic drug vehicles was investigated. The use of the polypropylene membrane as a control membrane for
Journal of drug targeting, 11(6), 373-379 (2003-12-12)
The aim of this study was to test the hypothesis that the most appropriate model for studying the diffusional release of an active from a topical formulation is one in which the membrane offers minimal resistance to release and involves
[Procedure for membrane oxygenation of blood over hydrophilic polymer membranes].
Biomedizinische Technik. Biomedical engineering, 43 Suppl, 338-340 (1998-12-22)
Artificial organs, 24(3), 168-173 (2000-04-12)
The introduction of microporous polypropylene hollow fibers in recent years has brought considerable advances to blood oxygenators. However, lifetime and assembly problems are still unresolved. In this work we tried to rate the oxygen permeation velocity by turning the fibers
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.