추천 제품
Quality Level
분석
97%
형태
solid
반응 적합성
core: boron
reagent type: catalyst
mp
>300 °C (lit.)
SMILES string
[K+].c1ccc(cc1)[B-](c2ccccc2)(c3ccccc3)c4ccccc4
InChI
1S/C24H20B.K/c1-5-13-21(14-6-1)25(22-15-7-2-8-16-22,23-17-9-3-10-18-23)24-19-11-4-12-20-24;/h1-20H;/q-1;+1
InChI key
MAMCUZQNCMYPCY-UHFFFAOYSA-N
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
Chemistry (Weinheim an der Bergstrasse, Germany), 25(16), 4166-4174 (2018-12-28)
The ability to tune the physical properties of bistable organic functional materials by means of chemistry can facilitate their development for molecular electronic switching components. The butylamine-containing biphenalenyl boron neutral radical, [Bu]2 B, crystalline compound has recently attracted significant attention
The Journal of organic chemistry, 73(22), 8683-8693 (2008-10-16)
1-Ethyl-2-(1-oxy-3-oxo-4,4,5,5-tetramethylimidazolin-2-yl)-3-methylimidazolium bromide, [EMINN](+)[Br](-), carrying nitronylnitroxide (NN) in the cation unit, was prepared as a parent molecule and converted to seven salts, [EMINN](+)[X](-) (X = I, TFSI (bis(trifluoromethanesulfonyl)imide), BPh4 (tetraphenylborate), [EMINN](+)(1-3)[BA(1-3)]((1-3)-); BA1 (benzoic acid), BA2 (terephthalic acid), and BA3 (trimesic acid)
Talanta, 83(3), 789-794 (2010-12-15)
A sensitive potentiometric surfactant sensor based on a highly lipophilic 1,3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate (TPB) antagonist ion was used as the end-point detector in ion-pair potentiometric surfactant titrations using sodium TPB as a titrant. Several analytical and technical grade
Talanta, 81(3), 1003-1009 (2010-03-20)
This paper focuses on the quantitative determination of the loss of the components from plastic membranes of ion-selective electrodes (ISEs) during contact with aqueous bathing solutions. The leaching processes, which affect the ISE responses, are rarely characterized by independent methods.
Talanta, 80(3), 1311-1317 (2009-12-17)
Two different derivatizing reagents were tested for the development of a fast and sensitive method for the determination of selenites (Se(IV)) in human urine. The reagents were sodium tetraethylborate (NaBEt(4)) and tetraphenylborate (NaBPh(4)), respectively, and the procedure is based on
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.