콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

1.13793

Supelco

PLC plates, Silica gel 60 F₂₅₄, 2 mm with concentrating zone 20 x 4 cm

pkg of 12 plates, plate L × W 20 cm × 20 cm, glass support

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115711
NACRES:
NB.21

material

glass support
silica gel 60 matrix

Quality Level

특징

binder Organic Polymer
fluorescent indicator

포장

pkg of 12 plates

기술

thin layer chromatography (TLC): suitable

레이어 두께

2 mm

플레이트 길이 × 너비

20 cm × 20 cm

입자 크기

20-40 μm

공극 크기

60 Å medium pore diameter

저장 온도

2-30°C

일반 설명

12 Glass plates 20 x 20 cm
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. Our concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the second is a selective layer for separation. Regardless of the spots’ shape, size, or position, the sample always concentrates as a narrow band where the two adsorbents overlap and where the separation starts. These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples.

애플리케이션


  • High-Performance Thin-Layer Chromatography (HPTLC): Silica gel 60 F₂₅₄ PLC plates are extensively used in HPTLC for separating and analyzing complex mixtures. These plates provide high resolution and selectivity for various analytes, including amino acids, peptides, and other organic compounds. Recent research highlights the effectiveness of these plates in separating dansyl derivatives of amino acids, demonstrating their importance in biochemical and clinical studies (Chomicki and Dzido, Current Issues in Pharmacy and Medical Sciences, 2022).

결합

Replaces: 13793-7; 13793

분석 메모

Layer thickness: 1700 - 2100 µm
Deviation of layer thickness per plate: ≤ 300 µm
layer thickness concentrating zone: 700 - 1100 µm
Fluctuation in the thickness of the concentration zone: ≤ 200 µm
Chromatographic testing:
colour test
hRf-values
- bleu vif organol, colour test, lipophile:
20 - 30
- Ceres Black G, colour test, lipophile: 45 - 55
- ceres Violet brn, colour test, lipophile: 60 - 75
Typical value determined on a conditioned plate
Eluent: toluene (45% rel. humidity)

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.