추천 제품
product name
Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
material
stainless steel column
Quality Level
Agency
suitable for USP L8
제품 라인
Purospher®
특징
endcapped: no
포장
1 ea of
라벨링 범위
3.5% Carbon loading
파라미터
250 bar pressure
60 °C max. temp.
기술
HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (Low - Medium)
컬럼 길이 × I.D.
15 cm × 4.6 mm
표면적
330 m2/g
기질
fully porous particle
기질 활성군
NH2 bonding phase
입자 크기
5 μm
공극 크기
120 Å pore size
operating pH range
2-7.5
분리 기술
hydrophilic interaction (HILIC)
normal phase
reversed phase
저장 온도
no temp limit
일반 설명
Purospher® STAR NH2, 5 µm HPLC columns are widely used for carbohydrate analysis, with a typical mobile phaseconsisting of acetonitrile and water. In terms of their polarity, these columns lie between bare silica and reversed-phase silica. Hence, Purospher® STAR NH2 can also be used as an ion-exchanger. In acidic solutions, the NH2-groups are protonated (-NH3 +X-) and therefore display the characteristics of a weak anion exchanger. Medium polarity Purospher® STAR NH2 columns possess hydrophilic as well as hydrophobic properties, thus can be used under both reversed-phase (HILIC) and normal-phase conditions. However, retention is weaker than on silica or RP-supports. Purospher® STAR NH2 columns are based on ultra-pure fully porous silica particles (Type B). Purospher® STAR NH2, 5 µm LiChroCART™ 150-4.6 is a cartridge column which requires a manuCART™ cartridge column holder part number 1.51486.0001.The recommended guard column is Purospher® STAR NH2 (5 µm) LiChroCART™ 4-4 part number 1.50267.0001. LiChroCART™ cartridge columns mounted with a manuCART™ cartridge column holder is hand-tight only and have therefore a maximum pressure stability of 250 bar.The column dimension of 150 mm length x 4.6 mm I.D. is the optimal choice for the HPLC separation of complex.Learn more about Purospher® STAR HPLC and UHPLC ColumnsLearn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection GuideBrochure: A Practical Guide to HPLC - Method Development Guide
애플리케이션
Intended to be used in the separation of alcohols,carboxylic acids, fat soluble vitamins, nucleotides, steroids, sugars, sugar alcohols, sweeteners, and water soluble vitamins.
특징 및 장점
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
분석 메모
Pressure: ≤ 45 bar
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
법적 정보
LICHROCART is a trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.