추천 제품
Grade
for metal titration
Quality Level
Agency
USP/NF
reag. Ph. Eur.
분석
≥98% (HPLC)
≥98.0%
기술
UV/Vis spectroscopy: suitable
titration: suitable
불순물
diphenylcarbazone, in accordance
≤0.1% insoluble matter in ethanol
무기 잔류물
≤0.05% (as SO4)
mp
170-175 °C (lit.)
170-175 °C
적합성
passes test for Hg detection
SMILES string
O=C(NNc1ccccc1)NNc2ccccc2
InChI
1S/C13H14N4O/c18-13(16-14-11-7-3-1-4-8-11)17-15-12-9-5-2-6-10-12/h1-10,14-15H,(H2,16,17,18)
InChI key
KSPIHGBHKVISFI-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
1,5-Diphenylcarbazide reaction with chromium(VI), has been widely used for the spectro- photometric determination of chromium. It is also an electron donor, and can be used for measuring photosystem 2 activity in subchloroplast fragments.
애플리케이션
1,5-diphenylcarbazide was used for preparing diphenylcarbazide solution, during an experimental procedure done for reducing biological chromium(VI), using trickling filter. It may be used for pre-column complexation in HPLC, during on-line preconcentration and determination of chromium(VI) traces in water.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
이미 열람한 고객
Oxidation of 1, 5-diphenylcarbazide as a measure of photosystem 2 activity in subchloroplast fragments.
Biochemical and Biophysical Research Communications, 36 (6), 878-884 (1969)
Biological chromium (VI) reduction using a trickling filter.
Journal of Hazardous Materials, 126 (1), 78-85 (2005)
On-line preconcentration and determination of chromium (VI) in waters by high-performance liquid chromatography using pre-column complexation with 1, 5-diphenylcarbazide.
Journal of Chromatography A, 808 (1), 193-199 (1998)
Biochemistry, 36(1), 76-85 (1997-01-07)
The behavior of photosystem II (PSII) reactions was investigated under conditions of decreasing water content by the addition of increasing concentrations of ethylene glycol (EG). The photosynthetic activities were measured for PSII samples either directly in aqueous solutions of EG
Analytical chemistry, 73(9), 2034-2040 (2001-05-17)
An automated continuous instrument for the collection and measurement of aerosol Cr(VI) is described. The system alternately collects the sample on one of two glass fiber filters. After 15-min sample collection on one filter, the sampling switches over to the
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..