콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

33490

Supelco

HMDI

analytical standard

동의어(들):

4,4′-Methylene-bis(cyclohexyl isocyanate), 4,4′-Diisocyanato-methylenedicyclohexane, 4,4′-HMDI, Bis(4-isocyanatocyclohexyl)methane

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH2(C6H10NCO)2
CAS Number:
Molecular Weight:
262.35
Beilstein:
2217800
EC Number:
MDL number:
UNSPSC 코드:
41116107
PubChem Substance ID:
NACRES:
NA.24

Grade

analytical standard

Quality Level

품질

mixture of isomers

유통기한

limited shelf life, expiry date on the label

기술

HPLC: suitable
gas chromatography (GC): suitable

응용 분야

environmental

형식

neat

SMILES string

O=C=NC1CCC(CC1)CC2CCC(CC2)N=C=O

InChI

1S/C15H22N2O2/c18-10-16-14-5-1-12(2-6-14)9-13-3-7-15(8-4-13)17-11-19/h12-15H,1-9H2

InChI key

KORSJDCBLAPZEQ-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food.

애플리케이션

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

픽토그램

Skull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 2 Inhalation - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 1

Flash Point (°F)

235.4 °F - closed cup

Flash Point (°C)

113 °C - closed cup

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Tzu-Wen Chuang et al.
Journal of biomedical materials research. Part A, 86(3), 648-661 (2007-11-21)
Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis; however, the immobilization of anticoagulant agents on the surface of the stent is a feasible method of improving stent compatibility. Heparin, a well-known anticoagulant, has
L H Chan-Chan et al.
Acta biomaterialia, 6(6), 2035-2044 (2009-12-17)
Biodegradable segmented polyurethanes (BSPUs) were prepared with poly(caprolactone) as a soft segment, 4,4'-methylene bis (cyclohexyl isocyanate) and either butanediol (BSPU1) or dithioerythritol (BSPU2) as a chain extender. BSPU samples were characterized in terms of their physicochemical properties and their hemocompatibility.
Extensive skin sensitization with minimal antibody production in guinea pigs as a result of exposure to dicyclohexylmethane-4,4'-diisocyanate.
M H Karol et al.
Toxicology and applied pharmacology, 65(2), 291-301 (1982-09-15)
I R White et al.
Contact dermatitis, 9(4), 300-303 (1983-07-01)
Organic di-isocyanates are used widely in industry. The concomitant respiratory complications are well-known. Cutaneous problems precipitated by skin contact with these chemicals are less well recognised. Allergic contact dermatitis caused by exposure to di-cyclohexylmethane 4,4'-di-isocyanate has been demonstrated in a
Y M Sun et al.
Biomaterials, 18(7), 527-533 (1997-04-01)
Composite membranes were prepared by casting a linear poly(2-hydroxyethyl methacrylate) (pHEMA) solution onto polyester non-woven supports, and then the supported pHEMA within the membranes was cross-linked by a diisocyanate cross-linking agent to form a network structure. The swelling and permeation

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.