추천 제품
Grade
analytical standard
Quality Level
vapor density
4.4 (vs air)
vapor pressure
0.03 mmHg ( 25 °C)
분석
≥99.7% (GC)
autoignition temp.
978 °F
유통기한
limited shelf life, expiry date on the label
expl. lim.
5.9 %
기술
HPLC: suitable
gas chromatography (GC): suitable
bp
218 °C (lit.)
mp
79.5-81.0 °C
80-82 °C (lit.)
응용 분야
cleaning products
cosmetics
environmental
food and beverages
personal care
형식
neat
SMILES string
c1ccc2ccccc2c1
InChI
1S/C10H8/c1-2-6-10-8-4-3-7-9(10)5-1/h1-8H
InChI key
UFWIBTONFRDIAS-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Naphthalene is widely used as an intermediate in the chemical and plastics industry. It is commonly found in petroleum, coal, mothballs, cigarette smoke, biomass burning, incomplete combustion, etc.
애플리케이션
Naphthalene is used as a calibration standard for the real-time quantification with high specificity for naphthalene vapor and other HOVs in industrial environment using NaDos personal exposure monitor (PEM) device.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 2 - Flam. Sol. 2
Storage Class Code
4.1B - Flammable solid hazardous materials
WGK
WGK 3
Flash Point (°F)
173.3 °F - closed cup
Flash Point (°C)
78.5 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges
이미 열람한 고객
Naphthalene DNA adduct formation and tolerance in the lung
Nucl. Instrum. Methods Phys. Res. Sect. B, 438, 119-123 (2019)
NaDos: A real-time, wearable, personal exposure monitor for hazardous organic vapors
Sensors and Actuators B, Chemical, 255, 2996-3003 (2018)
Determination of naphthalene metabolites in human urine by liquid chromatography?mass spectrometry with electrospray ionization
Journal of Chromatography A, 847(1-2), 9-17 (1999)
Nature genetics, 51(4), 728-738 (2019-02-20)
Characterizing the stem cells responsible for lung repair and regeneration is important for the treatment of pulmonary diseases. Recently, a unique cell population located at the bronchioalveolar-duct junctions has been proposed to comprise endogenous stem cells for lung regeneration. However
Journal of chromatography. A, 1280, 35-50 (2013-02-07)
The achievable separation speed and resolution of columns packed with the new 4.6 μm Kinetex particles were characterized by their permeability and their plate heights, measured meticulously. Their specific permeabilities range between 1.81 and 1.95 × 10(-10)cm(2) and their external
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.