추천 제품
Grade
for molecular biology
형태
powder
불순물
DNases, none detected
RNases, none detected
phosphatases, none detected
proteases, none detected
무기 잔류물
≤1%
손실
≤10% loss on drying
EEO
0.23-0.27
전이 온도
gel point 34-37 °C (1.5% solution)
겔 강도
≥1500 g/cm2
음이온 미량물
chloride (Cl-): ≤0.3%
sulfate (SO42-): ≤0.6%
양이온 미량물
Ca: ≤0.05%
Cd: ≤0.001%
Co: ≤0.001%
Cr: ≤0.001%
Cu: ≤0.001%
Fe: ≤0.001%
K: ≤0.05%
Mg: ≤0.001%
Mn: ≤0.001%
Na: ≤0.5%
Ni: ≤0.001%
Pb: ≤0.001%
Zn: ≤0.001%
InChI
1S/C24H38O19/c25-1-5-9(27)11(29)12(30)22(38-5)41-17-8-4-36-20(17)15(33)24(40-8)43-18-10(28)6(2-26)39-23(14(18)32)42-16-7-3-35-19(16)13(31)21(34)37-7/h5-34H,1-4H2/t5-,6-,7+,8+,9+,10+,11+,12-,13+,14-,15+,16-,17-,18+,19+,20+,21-,22+,23+,24+/m1/s1
InChI key
MJQHZNBUODTQTK-WKGBVCLCSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
생화학적/생리학적 작용
포장
50, 500 g in poly bottle
분석 메모
Sulfate content - used as an indicator of purity, since sulfate is the major ionic group present.
Gel strength - the force that must be applied to a gel to cause it to fracture.
Gel point - the temperature at which an aqueous agarose solution forms a gel as it cools. Agarose solutions exhibit hysteresis in the liquid-to-gel transition - that is, their gel point is not the same as their melting temperature.
Electroendosmosis (EEO) - a movement of liquid through the gel. Anionic groups in an agarose gel are affixed to the matrix and cannot move, but dissociable counter cations can migrate toward the cathode in the matrix, giving rise to EEO. Since electrophoretic movement of biopolymers is usually toward the anode, EEO can disrupt separations because of internal convection.
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)