콘텐츠로 건너뛰기
Merck
모든 사진(5)

문서

C2885

Sigma-Aldrich

CHES

≥99.0% (titration)

동의어(들):

2-(Cyclohexylamino)ethanesulfonic acid

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C8H17NO3S
CAS Number:
Molecular Weight:
207.29
Beilstein:
2967601
EC Number:
MDL number:
UNSPSC 코드:
12161700
PubChem Substance ID:
NACRES:
NA.25

분석

≥99.0% (titration)

형태

crystalline

pH

3.0-5.0 (103.6 g/L)

유용한 pH 범위

8.6-10.0

pKa(25 °C)

9.3

solubility

water: 0.6 g/25 mL, clear, colorless

응용 분야

diagnostic assay manufacturing

SMILES string

OS(=O)(=O)CCNC1CCCCC1

InChI

1S/C8H17NO3S/c10-13(11,12)7-6-9-8-4-2-1-3-5-8/h8-9H,1-7H2,(H,10,11,12)

InChI key

MKWKNSIESPFAQN-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

CHES (2-(N-cyclohexylamino)ethanesulphonic acid) is regarded as Good′s buffers for its self-buffering and biocompatible feature. It is used in protein stabilization and does not interact with metals.

애플리케이션

CHES has been used:
  • as a buffer in mannanase activity assay of antarctic fungal isolates
  • as a buffer for DNA digestion and labeling of 2′-deoxyadenosine 3′-monophosphate
  • as a component of Wilson and Horne extraction buffer for characterization of rat plasma enzymes

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

dust mask type N95 (US), Eyeshields, Gloves


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Slide 1 of 4

1 of 4

Determination of folate in some cereals and commercial cereal-grain products consumed in Poland using trienzyme extraction and high-performance liquid chromatography methods
Gujska E and Kuncewicz A
European Food Research and Technology, 221(1-2), 208-213 (2005)
Hemicellulase activity of antarctic microfungi
Bradner JR, et al.
Journal of Applied Microbiology, 87(3), 366-370 (1999)
Good's buffers as a basis for developing self-buffering and biocompatible ionic liquids for biological research
Taha M, et al.
Green Chemistry, 16(6), 3149-3159 (2014)
Detection of Bulky Endogenous Oxidative DNA Lesions Derived from 8, 5?-Cyclo-2?-deoxyadenosine by 32P-Postlabeling Assay
Zhou GD and Moorthy B
Current Protocols in Toxicology / Editorial Board, Mahin D. Maines (editor-in-chief) ... [Et al.], 64(1), 17-17 (2015)
P Doble et al.
Electrophoresis, 19(12), 2257-2261 (1998-10-07)
The suitability of relatively slow (low absolute value of mobility) coanionic buffers in background electrolytes (BGEs) for indirect photometric detection of anions by capillary electrophoresis was investigated. As a model system, 2-(cyclohexylamino)ethanesulfonic acid (CHES) was used to buffer the indirect

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.