추천 제품
product name
Sodium 3,5-dichloro-2-hydroxybenzenesulfonate, used for peroxide measurement
Quality Level
분석
≥98% (TLC)
형태
powder
기술
titration: suitable
색상
white to off-white
pH
7 (20 °C, 53 g/L)
mp
>300 °C
solubility
H2O: 50 mg/mL
응용 분야
diagnostic assay manufacturing
hematology
histology
저장 온도
room temp
SMILES string
[Na+].Oc1c(Cl)cc(Cl)cc1S([O-])(=O)=O
InChI
1S/C6H4Cl2O4S.Na/c7-3-1-4(8)6(9)5(2-3)13(10,11)12;/h1-2,9H,(H,10,11,12);/q;+1/p-1
InChI key
NMWCVZCSJHJYFW-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Sodium 3,5-dichloro-2-hydroxybenzenesulfonate is used in conjunction with 4-aminoantipyrine (4-AAP) and hydrogen peroxide (H2O2) for chromogenic quantitation of uric acid in serum and urine samples.
애플리케이션
Used in conjunction with 4-aminoantipyrine (4-AAP) and hydrogen peroxide (H2O2) for chromogenic quantitation of peroxidase in coupled enzymatic reactions. Component of Trinder reagent for use with peroxidase to measure generation of hydrogen peroxide in automated systems.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Talanta, 187, 83-90 (2018-06-02)
In this study, we have optimised the sterically directed attachment of biomolecules on the surface of coaxial membranes prepared by co-electrospinning which have been proved to be a material with very high performance for the development of biosensors with optical
Analytical and bioanalytical chemistry, 411(19), 4919-4928 (2019-04-04)
Microfluidic paper-based devices (μPADs) and wearable devices have been highly studied to be used as diagnostic tools due to their advantages such as simplicity and ability to provide instrument-free fast results. Diseases such as periodontitis and diabetes mellitus can potentially
Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymatic assay of uric acid in serum and urine.
Clinical Chemistry, 26(2), 227-231 (1980)
Clinical chemistry, 30(8), 1389-1392 (1984-08-01)
A colorimetric peroxidase-coupled procedure for determination of creatinine in human serum and urine is described. A 30-s sample pre-treatment with bilirubin oxidase eliminates interference from endogenous bilirubin. The 4-aminoantipyrine-2-hydroxy-3,5-dichlorobenzenesulfonate chromogen system of this method is about fourfold more sensitive than
Clinica chimica acta; international journal of clinical chemistry, 116(3), 301-309 (1981-11-11)
A uricase-peroxidase coupled system, for the determination of uric acid, applied to a CentrifiChem-500 centrifugal fast analyser is described. Relatively large amounts of ascorbic acid, due to the inclusion of an ascorbate oxidase urine diluent, and hemoglobin appear not to
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.