콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

21106

Supelco

GC Stationary Phase

phase SE-54, bottle of 50 g

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151817

Agency

meets requirements for USP G36

Quality Level

포장

bottle of 50 g

파라미터

50-300 °C temp. range

기술

gas chromatography (GC): suitable

기질 활성군

SE-54 phase

solubility

chloroform: soluble

컬럼 유형

packed GC

일반 설명

GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are a few parameters that should be considered before choosing a stationary phase. SE-54 is good for nonpolar phase as it provides better peak shapes for polar chemicals.
Synthesized specifically to be purer, of narrow molecular weight range, and without trace catalysts or impurities for use as a GC stationary phase.

애플리케이션

SE-54 is suitable for analysis of polycyclic aromatic hydrocarbons (PAH) and polychlorinated biphenyls (PCB) using PTE-5 fused silica capillary coulmn.

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

G Adami et al.
Journal of environmental monitoring : JEM, 2(3), 261-265 (2001-03-21)
A sediment sampling based on a two-dimensional mapping was performed in the harbour of Trieste (northern Adriatic Sea), considering 28 sites exposed to pollutant inputs from harbour and industrial activities. Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) were determined
Markku Mesilaakso
Chemical Weapons Convention Chemicals Analysis: Sample Collection, Preparation and Analytical Methods, 187-187 (2005)
Abhijit Ghosh et al.
Journal of chromatography. A, 1517, 134-141 (2017-09-01)
Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in
David B. Troy, Paul Beringer
Remington: The Science and Practice of Pharmacy, 605-605 (2006)
James P. Lodge, Jr.
Methods of Air Sampling and Analysis, 98-98 (1988)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.