Agency
meets requirements for USP G36
Quality Level
포장
bottle of 50 g
파라미터
50-300 °C temp. range
기술
gas chromatography (GC): suitable
기질 활성군
SE-54 phase
solubility
chloroform: soluble
컬럼 유형
packed GC
일반 설명
GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are a few parameters that should be considered before choosing a stationary phase. SE-54 is good for nonpolar phase as it provides better peak shapes for polar chemicals.
Synthesized specifically to be purer, of narrow molecular weight range, and without trace catalysts or impurities for use as a GC stationary phase.
애플리케이션
SE-54 is suitable for analysis of polycyclic aromatic hydrocarbons (PAH) and polychlorinated biphenyls (PCB) using PTE-5 fused silica capillary coulmn.
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves
가장 최신 버전 중 하나를 선택하세요:
Journal of environmental monitoring : JEM, 2(3), 261-265 (2001-03-21)
A sediment sampling based on a two-dimensional mapping was performed in the harbour of Trieste (northern Adriatic Sea), considering 28 sites exposed to pollutant inputs from harbour and industrial activities. Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) were determined
Chemical Weapons Convention Chemicals Analysis: Sample Collection, Preparation and Analytical Methods, 187-187 (2005)
Journal of chromatography. A, 1517, 134-141 (2017-09-01)
Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in
Remington: The Science and Practice of Pharmacy, 605-605 (2006)