29799-U

Supelco

SLB®-ILPAH Capillary GC Column

L × I.D. 20 m × 0.18 mm, df 0.05 μm

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115710
NACRES:
SB.54

material

fused silica

Quality Level

파라미터

≤25-300 °C temperature (isothermal or programmed)

베타 값

900

df

0.05 μm

기술

gas chromatography (GC): suitable

길이 × I.D.

20 m × 0.18 mm

기질 활성군

Non-bonded; 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide phase

응용 분야

food and beverages

컬럼 유형

capillary polar

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Application: This special purpose and specially tested capillary GC column is designed for the analysis of polycyclic aromatic hydrocarbons (PAHs). It incorporates an ionic liquid stationary phase. Each column is individually tested to ensure resolution of several key sets (phenanthrene/anthracene, benzo[a]anthracene/chrysene/triphenylene, and benzo [b]fluoranthene/benzo[k]fluoranthene/benzo[j]fluoranthene).
USP Code: None
Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide
Temp. Limits: Subambient to 300 °C (isothermal or programmed)

애플리케이션

Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity
This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017)

https://doi.org/10.1016/j.chroma.2017.01.026

Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity
The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures.
(Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.024

Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls
This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes.
(Anderson & Davis, 2019)
https://doi.org/10.1016/j.chroma.2

법적 정보

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean EZ-POP NP; both meet criteria.

프로토콜

Ionic liquid capillary GC columns enhance polar analyte inertness, addressing challenges in chromatography with improved stationary phases.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..