추천 제품
material
fused silica
Quality Level
파라미터
≤25-300 °C temperature (isothermal or programmed)
베타 값
900
df
0.05 μm
기술
gas chromatography (GC): suitable
길이 × I.D.
20 m × 0.18 mm
기질 활성군
Non-bonded; 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide phase
응용 분야
food and beverages
컬럼 유형
capillary polar
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Application: This special purpose and specially tested capillary GC column is designed for the analysis of polycyclic aromatic hydrocarbons (PAHs). It incorporates an ionic liquid stationary phase. Each column is individually tested to ensure resolution of several key sets (phenanthrene/anthracene, benzo[a]anthracene/chrysene/triphenylene, and benzo [b]fluoranthene/benzo[k]fluoranthene/benzo[j]fluoranthene).
USP Code: None
Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide
Temp. Limits: Subambient to 300 °C (isothermal or programmed)
USP Code: None
Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide
Temp. Limits: Subambient to 300 °C (isothermal or programmed)
애플리케이션
Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity
This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.026
Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity
The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures.
(Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.024
Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls
This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes.
(Anderson & Davis, 2019)
https://doi.org/10.1016/j.chroma.2
This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.026
Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity
The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures.
(Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.024
Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls
This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes.
(Anderson & Davis, 2019)
https://doi.org/10.1016/j.chroma.2
법적 정보
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
문서
Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean™ EZ-POP NP; both meet criteria.
프로토콜
Ionic liquid capillary GC columns enhance polar analyte inertness, addressing challenges in chromatography with improved stationary phases.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.