추천 제품
product name
Ascentis® Express F5, 2.7 μm HPLC Column, 2.7 μm particle size, L × I.D. 10 cm × 4.6 mm
material
stainless steel column
Quality Level
Agency
suitable for USP L43
제품 라인
Ascentis®
특징
endcapped
제조업체/상표
Ascentis®
포장
1 ea of
파라미터
60 °C temp. range
600 bar max. pressure (9000 psi)
기술
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
길이 × I.D.
10 cm × 4.6 mm
표면적
135 m2/g
불순물
<5 ppm metals
기질
Fused-Core particle platform
superficially porous particle
기질 활성군
PFP (pentafluorophenyl) phase
입자 크기
2.7 μm
공극 크기
90 Å pore size
작동 pH
2-8
응용 분야
food and beverages
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
애플리케이션
- Research on the Synthesis of Zinc-Ammonium Phosphate Using Galvanic Waste Sludge as a Source of Zinc.: This research investigates the synthesis of zinc-ammonium phosphate utilizing galvanic waste sludge, highlighting the analytical methods involving hydrochloric acid in the chemical recycling process (Morgovan et al., 2024).
- Chile′s agricultural research institute plant tissue analysis dataset.: This dataset encompasses analytical methods used for plant tissue analysis, with hydrochloric acid playing a key role in the preparation and analysis processes (Corradini et al., 2023).
- Determination of three plant growth regulators in Dendrobium officinale and Anoectochilus roxburghii by three-phase hollow fiber liquid phase microextraction- high performance liquid chromatography.: The study details a method using hydrochloric acid for the extraction and analysis of plant growth regulators, enhancing the accuracy of high-performance liquid chromatography techniques (Wu et al., 2023).
법적 정보
가아드 카트리지
관련 제품
애플리케이션
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
문서
This application note describes the LC-MS-based quantitative analysis of known nitrosamine impurities following procedures 1 and 3 as given in USP general chapter <1469>.
Enhanced selectivity for stereoisomers and closely related compounds with alternate selectivity from C18 phases for basic, acidic, or neutral compounds
프로토콜
Fast and Accurate LC-MS Analysis of Vitamin D Metabolites, Using Ascentis® Express F5 HPLC Columns from Supelco®
관련 콘텐츠
Accurately detect and quantify trace nitrosamines (NDMA, NDEA, NEIPA, NDIPA, NDBA, etc.) in pharmaceutical drugs using our complete product portfolio and application guides for LC-MS and GC-MS. Order high-quality reference standards, columns, filters & more.
Chromatograms
application for HPLCapplication for HPLCapplication for HPLC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.