Calcium standard solution

traceable to SRM from NIST Ca(NO₃)₂ in HNO₃ 0.5 mol/l 1000 mg/l Ca Certipur®

Sign Into View Organizational & Contract Pricing

Synonym(s):
Calcium reference standard solution for ICP/AAS
UNSPSC Code:
41116107
NACRES:
NA.24

grade

certified reference material

Quality Level

agency

suitable for EPA 200.7

product line

Certipur®

technique(s)

AAS: suitable

pH

0.5 (20 °C in H2O)

density

1.014 g/cm3 at 20 °C

application(s)

industrial qc
pharmaceutical

format

single component solution

storage temp.

15-25°C

Related Categories

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty and expiry date.

Application

The calcium standard solution may find its following use:
  • To determine metals in milk samples using flame atomic absorption spectroscopy (FAAS) and complexometric titration with EDTA
  • Estimation of calcium in grape must and base wine by fourier transform near-infrared (FT-NIR) spectroscopy
  • In the method development to determine calcium, magnesium, potassium, iron, copper, zinc, manganese and phosphorus in bread samples by microwave plasma-atomic emission spectrometry (MIP-AES)
  • Validation of an alternative method to measure calcium and magnesium in biological fluids
  • Determination of calcium and zinc in gluconate oral solutions and blood samples by liquid cathode glow discharge-atomic emission spectroscopy (LCGD-AES)
  • Development and validation of an inductively coupled plasma-atomic emission spectroscopy (ICP-AES) based method to determine trace elements in vinegar

Other Notes

For a complete product listing of our Certipur® range of CRMs for ICP and AAS, technical information, and example certificates please visit our ICP & AAS standards website

Legal Information

CERTIPUR is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

Corrosion

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 9

1 of 9

Sodium standard solution traceable to SRM from NIST NaNO₃ in H₂O 1000 mg/l Na Certipur®

Supelco

1.19507

Sodium standard solution

Chromium standard solution traceable to SRM from NIST Cr(NO₃)₃ in HNO₃ 0.5 mol/l 1000 mg/l Cr Certipur®

Supelco

1.19779

Chromium standard solution

Supelco

Supelco

19051

Calcium Standard for ICP

Boron standard solution traceable to SRM from NIST H₃BO₃ in H₂O 1000 mg/l B Certipur®

Supelco

1.19500

Boron standard solution

Zinc standard solution traceable to SRM from NIST Zn(NO₃)₂ in HNO₃ 0.5 mol/l 1000 mg/l Zn Certipur®

Supelco

1.19806

Zinc standard solution

Chloride standard solution traceable to SRM from NIST NaCl in H₂O 1000 mg/l Cl Certipur®

Supelco

1.19897

Chloride standard solution

Lithium standard solution traceable to SRM from NIST LiNO₃ in HNO₃ 0.5 mol/l 1000 mg/l Li Certipur®

Supelco

1.70223

Lithium standard solution

Iron standard solution traceable to SRM from NIST Fe(NO₃)₃ in HNO₃ 0.5 mol/l 1000 mg/l Fe Certipur®

Supelco

1.19781

Iron standard solution

Predicting calcium in grape must and base wine by FT-NIR spectroscopy
Vestia J, et al.
Food Chemistry, 276, 71-76 (2019)
Development and Validation of an Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) Method for Trace Element Determination in Vinegar
Paktsevanidou IP, et al.
Analytical Letters, 54(13), 2227-2238 (2021)
Characterization and validation of candidate reference methods for the determination of calcium and magnesium in biological fluids
Aljerf L and Mashlah A
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 132, 411-421 (2017)
Determination of calcium and zinc in gluconates oral solution and blood samples by liquid cathode glow discharge-atomic emission spectrometry
Yu J, et al.
Talanta, 175, 150-157 (2017)
Comparative study for the determination of metals in milk samples using flame-AAS and EDTA complexometric titration
Hussain Z, et al.
Journal of science, technology and environment, 40(1), 1-6 (2010)

Protocols

Using the Spectroquant® photometric system, we outline a photometric analysis of calcium levels in beer.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service