P3B050A00
Pellicon® 3 Cassette with Biomax® Membrane
50kDa, A Screen, 88 cm2
Synonym(s):
Pellicon® 3 Cassette with Biomax® 50 kDa Membrane, A Screen, 88cm2
About This Item
Recommended Products
material
TPE seal
polyethersulfone membrane (void free)
polypropylene
polypropylene cap (for end)
polypropylene screen
Quality Level
feature
holdup volume 1.8 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
5.5 bar max. inlet pressure (80 psi) at 30 °C
5.5 bar max. transmembrane pressure (80 psig) at 30 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)
H
0.8 cm (0.33 in.)
L
20.6 cm (8.1 in.)
W
5.6 cm (2.2 in.)
filtration area
88 cm2
Related Categories
1 of 4
This Item | P3B010A00 | P3B030A00 | P3B050A05 |
---|---|---|---|
analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable | analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | buffer exchange: suitable, protein purification: suitable (concentration) | analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) |
88 cm2 | 88 cm2 | 88 cm2 | - |
Biomax® (Membrane) | Biomax® (Membrane) | Biomax® (Membrane) | Biomax® (Membrane) |
TPE seal, polypropylene , polypropylene screen, polyethersulfone membrane (void free), polypropylene cap (for end) | TPE seal, polyethersulfone membrane (void free), polypropylene , polypropylene cap (for end), polypropylene screen | TPE seal, polyethersulfone membrane (void free), polypropylene , polypropylene cap (for end), polypropylene screen | TPE seal, polyethersulfone , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated) |
30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 80 psi max. transmembrane pressure at 4-40 °C | 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 30 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C |
General description
The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.
This P3B050A00 Pellicon® 3 ultrafiltration device features a pore size of 50 kDa NMWCO, a filtration area of 88 cm2, a Biomax® 50 membrane, and dimensions measuring 0.8 cm (H) x 5.6 cm (W) x 20.6 cm (L).
Features and Benefits
- Rugged & reliable – ideally suited for today′s more demanding filtration processes
- High performance – produces excellent resolution, yields and back-pressure resistance
- Optimum product recovery – thanks to proven membrane technology
- Void-free technology – leading-edge membranes resolve virtually any separation challenge
- Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
- Automated manufacturing – delivers unbeatable performance, consistency and reliability
- Easy installation & care – simple to install and maintain
Other Notes
Analysis Note
Legal Information
Storage Class
8B - Non-combustible corrosive hazardous materials
wgk_germany
WGK 1
What is the Emprove® Program?
The Emprove® Program is a system providing comprehensive and thorough documentation of our filters and single-use components, pharma raw materials, and starting materials. Four document types are included with an Emprove® Program subscription:
Free of charge - Sign in to download
Free of charge - Sign in to download
Available by subscription or for a fee
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service