MilliporeSigma
All Photos(1)

Documents

81392

Supelco

Poly(vinyl chloride)

Selectophore, high molecular weight

Synonym(s):
PVC
Linear Formula:
(CH2CHCl)n
CAS Number:
MDL number:
PubChem Substance ID:
NACRES:
NB.61

grade

for ion-selective electrodes

Quality Level

product line

Selectophore

form

powder

viscosity

2.0-5.0 mPa.s, 3 % in THF(25 °C)

density

1.4 g/mL at 25 °C (lit.)

SMILES string

ClC=C

InChI

1S/C2H3Cl/c1-2-3/h2H,1H2

InChI key

BZHJMEDXRYGGRV-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Poly(vinyl chloride), popular as PVC, is a polymer which is prepared from vinyl chloride monomer via polymerisation. It can never be used as such and is mostly mixed with heat stabilizers, lubricants, plasticizers, fillers, and other additives. Due to its high chemical resistance property it finds wide application in construction and lining of chemical plants.
Visit our Sensor Applications portal to learn more.

Application

It has been used to fabricate Aluminum(III) selective potentiometric sensor from PVC matrix membrane which has morin ionophore.

Legal Information

Selectophore is a trademark of Sigma-Aldrich Chemie GmbH

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 7

1 of 7

Poly(vinyl chloride) European Pharmacopoeia (EP) Reference Standard

P2600000

Poly(vinyl chloride)

Potassium ionophore I Selectophore™, function tested

Supelco

60403

Potassium ionophore I

Polyvinyl Chloride Plasticide United States Pharmacopeia (USP) Reference Standard

USP

1544916

Polyvinyl Chloride Plasticide

Sodium ionophore X Selectophore™, function tested

Supelco

71747

Sodium ionophore X

Bis(1-butylpentyl) adipate Selectophore™, ≥98.0%

Supelco

02150

Bis(1-butylpentyl) adipate

Polyvinyl chloride United States Pharmacopeia (USP) Reference Standard

USP

1548076

Polyvinyl chloride

Aluminum (III) selective potentiometric sensor based on morin in poly (vinyl chloride) matrix.
Gupta, Vinod K., Ajay K. Jain, and Gaurav Maheshwari.
Talanta, 72.4, 1469-1473 (2007)
Poly (vinyl chloride).
Allsopp, Michael W., and Giovanni Vianello.
Ullmann's Encyclopedia of Industrial Chemistry (1992)
Michal Ciborowski et al.
Journal of proteome research, 11(12), 6231-6241 (2012-11-15)
Ozonated autohemotherapy (O3-AHT) is a medical approach during which blood obtained from the patient is ozonated and injected back into the body. Despite an increasing number of evidence that O3-AHT is safe, this type of therapy remains controversial. To extend
Jeffrey S Souris et al.
Molecular imaging, 12(1), 28-38 (2013-01-26)
At present, there is considerable interest in the use of in vivo fluorescence and bioluminescence imaging to track the onset and progression of pathologic processes in preclinical models of human disease. Optical quantitation of such phenomena, however, is often problematic
Gianluigi Li Bassi et al.
Critical care medicine, 41(2), 518-526 (2012-12-25)
To assess the structural characteristics involved in the design of high-volume low-pressure endotracheal tube cuffs that are associated with fluid sealing effectiveness and to determine the extent of transmitted tracheal pressures upon cuff inflation. In vitro study. Pneumology laboratories. Eight

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service