MilliporeSigma
All Photos(2)

Documents

21014

Supelco

LpDNPH S10 Cartridge

bed wt. 350 mg, volume 3 mL, pkg of 50 ea

Agency

ASTM® D5197
EPA 100,IP-6A,TO-11A
NIOSH 2016

Quality Level

composition

bed wt., 350 mg
High Purity Silica Gel Coated with 2,4-dinitrophenylhydrazine (DNPH)

packaging

pkg of 50 ea

technique(s)

active air sampling: suitable

volume

3 mL

application(s)

air monitoring
environmental
industrial hygiene

storage temp.

2-8°C

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
505358505293505315
LpDNPH S10 Cartridge bed wt. 350 mg, volume 3 mL, pkg of 50 ea

Supelco

21014

LpDNPH S10 Cartridge

LpDNPH S10L Cartridge bed wt. 350 mg, volume 1 mL, pkg of 10 ea

Supelco

505358

LpDNPH S10L Cartridge

LpDNPH S10x Cartridge bed wt. 350 mg, volume 1.5 mL, pkg of 10 ea

Supelco

505293

LpDNPH S10x Cartridge

LpDNPH H Series Cartridges H10, volume 3 mL

Supelco

505315

LpDNPH H Series Cartridges

composition

bed wt., 350 mg , High Purity Silica Gel Coated with 2,4-dinitrophenylhydrazine (DNPH)

composition

bed wt., 350 mg , High Purity Silica Gel Coated with 2,4-dinitrophenylhydrazine (DNPH)

composition

bed wt., 350 mg , High Purity Silica Gel Coated with 2,4-dinitrophenylhydrazine (DNPH)

composition

High Purity Silica Gel Coated with 2,4-dinitrophenylhydrazine (DNPH)

technique(s)

active air sampling: suitable

technique(s)

active air sampling: suitable

technique(s)

active air sampling: suitable

technique(s)

active air sampling: suitable

volume

3 mL

volume

1 mL

volume

1.5 mL

volume

3 mL

packaging

pkg of 50 ea

packaging

pkg of 10 ea

packaging

pkg of 10 ea

packaging

pkg of 10 ea

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

General description

The design of the S10 cartridge makes it easy to use in the field and laboratory. Reusable adaptors are available for connecting the cartridge to the sampling pump. The built in reservoir eliminates the need to attach a syringe for sample extraction/elution.

Application

LpDNPH S10 Cartridge was suitable as sampling apparatus for aldehydes while performing gas chromatography. It was also used to sample DNPH derivatives to perform HPLC and GC-MS to measure and characterize DNOH derivatives of aldehydes and ketone.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 9

1 of 9

LpDNPH S10x Cartridge bed wt. 350 mg, volume 1.5 mL, pkg of 10 ea

Supelco

505293

LpDNPH S10x Cartridge

LpDNPH Ozone Scrubber Rezorian Cartridge, Potassium Iodide (KI) 1.5 g

Supelco

54078-U

LpDNPH Ozone Scrubber

LpDNPH S10L Cartridge bed wt. 350 mg, volume 1 mL, pkg of 50 ea

Supelco

505361-U

LpDNPH S10L Cartridge

BPE-DNPH Cartridge volume 3 mL, bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), pkg of 50 ea

Supelco

54279-U

BPE-DNPH Cartridge

BPE-DNPH Cartridge bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), volume 3 mL, pkg of 10 ea

Supelco

54278-U

BPE-DNPH Cartridge

Mehrdad Arshadi et al.
The Annals of occupational hygiene, 53(8), 797-805 (2009-08-12)
Different qualities of biofuel pellets were made from pine and spruce sawdust according to an industrial experimental design. The fatty/resin acid compositions were determined by gas chromatography-mass spectrometry for both newly produced pellets and those after 2 and 4 weeks
Kuo-Pin Yu et al.
Journal of the Air & Waste Management Association (1995), 56(5), 666-674 (2006-06-03)
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor

Related Content

Air Monitoring

Air monitoring is used to measure the level of air pollutants in environmental, industrial, or indoor settings to assess the air quality per standards established by health and regulatory agencies.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service