コンテンツへスキップ
Merck

266647

Sigma-Aldrich

コバルト

powder, <150 μm, ≥99.9% trace metals basis

別名:

Cobalt element, Cobalt-59

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
Co
CAS番号:
分子量:
58.93
EC Number:
MDL番号:
UNSPSCコード:
12141710
PubChem Substance ID:
NACRES:
NA.23

品質水準

アッセイ

≥99.9% trace metals basis

フォーム

powder

抵抗性

6.24 μΩ-cm, 20°C

粒径

<150 μm

bp

2900 °C (lit.)

密度

8.9 g/mL at 25 °C (lit.)

SMILES記法

[Co]

InChI

1S/Co

InChI Key

GUTLYIVDDKVIGB-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

Cobaltpowder is a metallic powder of the element cobalt (Co), typically produced through reduction or electrolysis. Our high-purity cobalt powder is characterized by its particle size of less than 150 μm and a purity of ≥99.9% on a trace metals basis. It is used in lithium-ion batteries for enhancing their stability and energy density for portable electronics, electric vehicles, and renewable energy storage systems. Additionally, it is also used as a binder in hard alloys, it tightly binding the hard phase of the material, such as tungstencarbide, through powder metallurgy sintering.

アプリケーション

太陽電池用途や、表面走査測定に理想的な特性を持ち、また、不純物のない原子レベルで平坦な表面を持つ、金属を多く含む層状テルル化合物TaCo2Te2 の合成に用いられます

ピクトグラム

FlameHealth hazard

シグナルワード

Danger

危険有害性の分類

Aquatic Chronic 4 - Carc. 1B - Eye Irrit. 2 - Flam. Sol. 1 - Muta. 2 - Repr. 1B - Resp. Sens. 1 - Skin Sens. 1

保管分類コード

4.1B - Flammable solid hazardous materials

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable

個人用保護具 (PPE)

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

PRTR

第一種指定化学物質

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

266647-BULK:
266647-VAR:
266647-250G:4548173313658
266647-50G:4548173313665


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Slide 1 of 8

1 of 8

コバルト powder, max. particle size 7.5 micron, weight 200&#160;g, purity 99.6%

GF13438751

コバルト

ニッケル powder, &lt;150&#160;&#956;m, 99.99% trace metals basis

Sigma-Aldrich

203904

ニッケル

マンガン powder, &#8805;99.9% trace metals basis

Sigma-Aldrich

463728

マンガン

コバルト Carbon coated magnetic, nanopowder, &lt;50&#160;nm particle size (TEM), &#8805;99%

Sigma-Aldrich

697745

コバルト

ニッケル wire, diam. 0.5&#160;mm, &#8805;99.9% trace metals basis

Sigma-Aldrich

357626

ニッケル

コバルト foil, thickness 1.0&#160;mm, 99.95% trace metals basis

Sigma-Aldrich

356891

コバルト

マンガン powder, &#8722;325&#160;mesh, &#8805;99% trace metals basis

Sigma-Aldrich

266132

マンガン

クロム powder, &#8805;99% trace metals basis, &lt;45&#160;&#956;m

Sigma-Aldrich

266299

クロム

Neuhasen, J. et al.
Chemistry of Materials, 10, 3870-3870 (1998)
Pushya A Potnis et al.
Cellular immunology, 282(1), 53-65 (2013-05-18)
Metal orthopedic implant debris-induced osteolysis of hip bone is a major problem in patients with prosthetic-hips. Although macrophages are the principal targets for implant-wear debris, the receptor(s) and mechanisms underlying these responses are not fully elucidated. We examined whether the
Takuya Kurahashi et al.
Inorganic chemistry, 52(7), 3908-3919 (2013-03-23)
The Co(salen)(X) complex, where salen is chiral N,N'-bis(3,5-di-tert-butylsalicylidene)-1,2-cyclohexanediamine and X is an external axial ligand, has been widely utilized as a versatile catalyst. The Co(salen)(X) complex is a stable solid that has been conventionally described as a Co(III)(salen)(X) complex. Recent
Dilemmas about the toxicological consequences of metal-on-metal hip prostheses -- What we do and do not know, and what we should do?
Jeffrey Brent et al.
Clinical toxicology (Philadelphia, Pa.), 51(4), 195-198 (2013-04-06)
Jeannette Ø Penny et al.
Acta orthopaedica, 84(2), 130-137 (2013-04-20)
Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) and investigated

資料

Permanent magnets are an essential technology for energy conversion. Motors and generators are used to convert energy between electrical and mechanical forms.

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)