コンテンツへスキップ
Merck

803391

Sigma-Aldrich

SM(PEG)24 (PEGylated, long-chain SMCC crosslinker)

別名:

PEGylated SM(PEG)24

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
C62H111N3O31
UNSPSCコード:
12161502
NACRES:
NA.22

形状

powder

品質水準

分子量

1394.55

反応適合性

reagent type: cross-linking reagent

保管条件

desiccated

輸送温度

ambient

保管温度

−20°C

SMILES記法

O=C(N1OC(CCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCNC(CCN2C(C=CC2=O)=O)=O)=O)CCC1=O

詳細

SM(PEG)n NHS- and maleimide-activated PEG compounds for crosslinking between primary amines (NH2) and sulfhydryl (SH) groups in proteins and other molecules. A complete set of compounds are offered, each having the same heterobifunctional structure (NHS-PEGn-Maleimide) but differing in the number of discrete ethylene glycol units ( n = 2, 4, 6, 8, 12 or 24). The N-hydroxysuccinimide ester (NHS) group reacts specifically and efficiently with lysine and N-terminal amino groups at pH 7-9 to form stable amide bonds. The maleimide group reacts with reduced sulfhydryls at pH 6.5-7.5 to form stable thioether bonds

アプリケーション

SM(PEG)24 can be used as a crosslinker in:
  • The study of chemical cross-linking of glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and RNAses using the high-mass MALDI-MS technique.
  • Preparation of protein G-liposomal nanovesicles applicable as sensors in the detection of gentamycin in the milk sample.
  • Conjugation of catalase to streptavidin, which is helpful in the detection of analytes at very low concentrations using ELISA technique.

特徴および利点

  • Reactive groups: NHS ester and maleimide
  • Reactive toward: amino and sulfhydryl groups
  • Irreversibly crosslink proteins or peptides by flexible PEG spacer arms
  • Polyethylene glycol spacer arms help maintain conjugate solubility
  • Pure compound with defined structure and molecular weight, ensuring reproducible protein-modification effects
  • PEG spacer provides unique advantages, including increased stability, reduced tendency toward aggregation and reduced immunogenicity
  • Ideal for performing controlled, two-step protein conjugations (see Sulfo-SMCC)

注意

This product is sensitive to moisture. The vial is packaged in a resealable bag with a desiccant to reduce exposure to moisture. After cold storage, equilibrate the vial to room temperature before opening to reduce condensation inside the vial. Make fresh solutions. Storage of stock solutions is not recommended. After use, return the vial to the resealable bag. Close the bag and store the product at the recommended temperature.

保管分類コード

11 - Combustible Solids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

803391-100MG:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Development of a novel bead-based 96-well filtration plate competitive immunoassay for the detection of Gentamycin
Ho TYJ, et al.
Biosensors And Bioelectronics, 49(7), 126-132 (2013)
Understanding chemical reactivity for homo-and heterobifunctional protein cross-linking agents
Chen F, et al.
Journal of Mass Spectrometry : Jms, 48(7), 807-812 (2013)
Plasmonic ELISA for the detection of analytes at ultralow concentrations with the naked eye
De La Rica R and Stevens MM
Nature Protocols, 8(9), 1759-1759 (2013)

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)