おすすめの製品
品質水準
テクニック
ion chromatography: suitable
pH
9-10 (20 °C in H2O)
密度
1.00 g/cm3 at 20 °C
アプリケーション
environmental
food and beverages
フォーマット
single component solution
保管温度
2-8°C
アプリケーション
- Development of Cyanide Detection Methods: Utilizing high-performance liquid chromatography-tandem mass spectrometry, researchers have developed concurrent determination methods for cyanide and thiocyanate in human and swine blood. This technique ensures high accuracy and sensitivity, crucial for toxicological analysis and forensic investigations (Alluhayb et al., 2023).
- Fluorometric Cyanide Sensing: A novel fluorometric probe offers high selectivity for sensing cyanide in aqueous solutions, which can be applied to quantitative determinations and living cell imaging. This advancement supports biochemical assays requiring precise cyanide measurements, enhancing safety and detection capabilities in both environmental and clinical settings (Satheeshkumar et al., 2023).
アナリシスノート
Concentration β (CN⁻): 990 - 1010 mg/l
Determination method: Argentometric titration.
The content of this solution was determined with silver nitrate standard solution (article number 1.09081) standardized against volumetric standard sodium chloride (article number 1.02406). The expanded measurement uncertainty is ± 0.7 % (k=2 coverage factor for 95% coverage probability). The certified value is traceable to primary standard NIST SRM 999b (NIST: National Institute of Standards and Technology, USA) by means of volumetric standard sodium chloride, measured in the accredited calibration laboratory of Merck KGaA, Darmstadt, Germany in accordance to DIN EN ISO/IEC 17025.
Determination method: Argentometric titration.
The content of this solution was determined with silver nitrate standard solution (article number 1.09081) standardized against volumetric standard sodium chloride (article number 1.02406). The expanded measurement uncertainty is ± 0.7 % (k=2 coverage factor for 95% coverage probability). The certified value is traceable to primary standard NIST SRM 999b (NIST: National Institute of Standards and Technology, USA) by means of volumetric standard sodium chloride, measured in the accredited calibration laboratory of Merck KGaA, Darmstadt, Germany in accordance to DIN EN ISO/IEC 17025.
法的情報
CERTIPUR is a registered trademark of Merck KGaA, Darmstadt, Germany
危険有害性情報
注意書き
危険有害性の分類
Aquatic Chronic 3
補足的ハザード
保管分類コード
12 - Non Combustible Liquids
WGK
WGK 2
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
毒物及び劇物取締法
毒物
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)