A10® TOC Monitor can be used for the accurate online measurement of total organic carbon (TOC) content in ultrapure water delivered by Milli-Q® water purification systems without a built-in TOC monitor. It is compatible with any high purity water laboratory system.
アプリケーション
A10® TOC Monitor is an ideal accessory for use in water monitoring. It is reported for use in the measurement of TOC/organic content in purified water and in water used as eluent in LC-MS studies.
特徴および利点
- High accuracy enabled by complete oxidation of organics to their end-point reaction, attributed to oxidation and conductivity measurements occurring within the same cell.
- Range (1 – 999) and precision passing USP & EP suitability tests according to Milli-Q® Quality Assurance System standard procedures and specifications.
- Traceability of measurement equipment is performed as per the Milli-Q® Calibration System. Certification of calibration is provided to comply with the industry requirements. A10® TOC Monitor can be recalibrated at user request and has been designed to take into account the suitability test requirements as specified in USP <643>.
法的情報
A10 is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
Analytical chemistry, 87(9), 4836-4843 (2015-04-07)
Highly oriented pyrolytic graphite (HOPG) is an important electrode material as a structural model of graphitic nanocarbons such as graphene and carbon nanotubes. Here, we apply scanning electrochemical microscopy (SECM) to demonstrate quantitatively that the electroactivity of the HOPG basal
Journal of chromatography. A, 1030(1-2), 289-295 (2004-03-27)
Improvements in trace enrichment techniques combined with the sensitivity of mass spectrometry offer enhanced opportunities to analyze ever lower concentrations of drugs, metabolites, pesticides or environmental pollutants. To perform HPLC and liquid chromatography-mass spectrometry (LC-MS) analyses under optimum conditions, the
Water research, 40(17), 3239-3248 (2006-08-30)
To determine the disinfection efficacy of ozonation, water companies can apply several disinfection calculation methods. The goal of this study was to evaluate the use of the T10 and continuous stirred tank reactor (CSTR) method to extrapolate inactivation rates of
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)