おすすめの製品
詳細
Each unit of SRM 1155a is a solid disk measuring 3.2 cm in diameter and 1.9 cm in thickness.
SRM 1155A_cert
SRM 1155A_SDS
SRM 1155A_cert
SRM 1155A_SDS
アプリケーション
- HPLC-UV and GC-MS Methods for Determination of Chlorambucil and Valproic Acid in Plasma for Further Exploring a New Combined Therapy of Chronic Lymphocytic Leukemia.: This study employed the LiChrospher® 100 RP-18 endcapped (10 µm) LICHROCART™ 250-4 column for the high-performance liquid chromatography analysis of chlorambucil and valproic acid in plasma. The method facilitated efficient separation and detection, critical for evaluating combined chemotherapy protocols (Lipska K et al., 2021).
- Application of chemometric approach for development and validation of high performance liquid chromatography method for estimation of ropinirole hydrochloride.: This research utilized the LiChrospher® 100 RP-18 endcapped column to develop and validate a robust HPLC method for the quantification of ropinirole hydrochloride. The study demonstrated the column′s capability in achieving high sensitivity and precision in pharmaceutical analysis (Fatima S et al., 2019).
- Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.: The LiChrospher® 100 RP-18 endcapped column was applied in the analysis of retinol and its esters in human plasma. This study showcased the column′s efficiency in separating closely related compounds, essential for accurate biochemical assays (Hartmann S et al., 2001).
- Rapid, highly sensitive method for the determination of morphine and its metabolites in body fluids by liquid chromatography-mass spectrometry.: This investigation leveraged the LiChrospher® 100 RP-18 endcapped column to develop a sensitive LC-MS method for morphine and its metabolites. The column′s performance ensured reliable detection in forensic and clinical toxicology (Schänzle G et al., 1999).
- Determination of 13-cis-3-hydroxyretinoic acid, all-trans-3-hydroxyretinoic acid and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and UV detection.: This study used the LiChrospher® 100 RP-18 endcapped column for the simultaneous analysis of retinoic acid metabolites, highlighting its application in pharmacokinetics and metabolism research (Wyss R et al., 1998).
- Determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.: The research focused on using the LiChrospher® 100 RP-18 endcapped column for analyzing endogenous retinoic acids in plasma, demonstrating the column′s utility in clinical biochemistry and toxicology studies (Wyss R et al., 1997).
特徴および利点
- Accompanied with certificate documenting NIST-certified and reference mass fraction values, and coverage factor(k) for elements in stainless steel matrix of SRM1155A.
- Information values for elements are reported as mass fractions.
- The certified values are metrologically traceable to the derived SI unit of mass, expressed in %.
- The NIST certificate is provided with expiration certificate, storage, handling,use, and maintenance instructions.
その他情報
Certified for the analytes listed below.
Carbon (C), Cobalt (Co), Chromium (Cr), Copper (Cu), Iron (Fe), Manganese (Mn), Molybdenum (Mo), Niobium (Nb), Nickel (Ni), Phosphorus (P), Silicon (Si), Titanium (Ti), Vanadium (V), Tungsten (W).
Reference/Informational value is provided for the following analytes.
Arsenic (As), Nitrogen (N), Sulfur (S), Tin (Sn), Aluminum (Al), Boron (B), Bismuth (Bi), Lead (Pb), Oxygen (O)
See certificate for values and more details at nist.gov/SRM.
Carbon (C), Cobalt (Co), Chromium (Cr), Copper (Cu), Iron (Fe), Manganese (Mn), Molybdenum (Mo), Niobium (Nb), Nickel (Ni), Phosphorus (P), Silicon (Si), Titanium (Ti), Vanadium (V), Tungsten (W).
Reference/Informational value is provided for the following analytes.
Arsenic (As), Nitrogen (N), Sulfur (S), Tin (Sn), Aluminum (Al), Boron (B), Bismuth (Bi), Lead (Pb), Oxygen (O)
See certificate for values and more details at nist.gov/SRM.
法的情報
LICHROCART is a trademark of Merck KGaA, Darmstadt, Germany
LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
関連製品
製品番号
詳細
価格
保管分類コード
13 - Non Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
PRTR
第一種指定化学物質
労働安全衛生法名称等を表示すべき危険物及び有害物
名称等を表示すべき危険物及び有害物
労働安全衛生法名称等を通知すべき危険物及び有害物
名称等を通知すべき危険物及び有害物
Jan Code
NIST1155A:
最新バージョンのいずれかを選択してください:
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)