추천 제품
포함
MEHQ as inhibitor
250-500 ppm MEHQ as inhibitor
Quality Level
refractive index
n20/D 1.557 (lit.)
점도
2000-4000 cP(65 °C)(lit.)
산성 번호
<5 mg KOH/g
density
1.18 g/mL at 25 °C (lit.)
SMILES string
CC(C)(c1ccc(OCC(O)COC(=O)C=C)cc1)c2ccc(OCC(O)COC(=O)C=C)cc2
InChI
1S/C27H32O8/c1-5-25(30)34-17-21(28)15-32-23-11-7-19(8-12-23)27(3,4)20-9-13-24(14-10-20)33-16-22(29)18-35-26(31)6-2/h5-14,21-22,28-29H,1-2,15-18H2,3-4H3
InChI key
VZTQQYMRXDUHDO-UHFFFAOYSA-N
애플리케이션
UV curable cross-linking agent. Component of curable inks, coatings, varnishes and lacquers.
특징 및 장점
High viscosity, non-volatile, difunctional acrylate. Gives fast cure speeds, low odor and low volatility.
물리적 형태
epoxy acrylate oligomer
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Skin Sens. 1
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
235.4 °F - closed cup
Flash Point (°C)
113 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Sensitization capacity of acrylated prepolymers in ultraviolet curing inks tested in the guinea pig.
Acta dermato-venereologica, 61(1), 7-10 (1981-01-01)
One commonly used prepolymer in ultraviolet (UV) curing inks is epoxy acrylate. Of 6 men with dermatitis contracted from UV-curing inks, 2 had positive patch test reaction to epoxy acrylate. None reacted to the chemically related bisphenol A dimethacrylate. The
Contact dermatitis, 28(4), 216-219 (1993-04-01)
Epoxy resin of the bisphenol A type (ERBA) is a common cause of occupational contact dermatitis. 167 patients with a history of potential exposure were patch tested with epoxy resin (molecular weight 340) (ERBAM) 1% in pet. and with a
Electrophoresis, 33(16), 2591-2597 (2012-08-18)
Manufacturing materials are an essential element for the fabrication of microfluidic chips. PDMS, the most widely used polymeric material, is associated with apparent disadvantages such as hydrophobic nature, while other materials also suffer from some limitations. In this paper, a
Contact dermatitis, 14(2), 80-84 (1986-02-01)
A dental assistant developed sensitivity to dental restorative materials within 3 months of starting to use them. They contained the epoxy acrylate BIS-GMA, which is the most commonly used dimethacrylate monomer in dental composite restorations. She was positive to a
Contact dermatitis, 61(1), 9-21 (2009-08-08)
Contact allergy to epoxy (meth)acrylates, 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl]propane (bis-GMA), 2,2-bis[4-(2-hydroxy-3-acryloxypropoxy)phenyl]-propane (bis-GA), 2,2-bis[4-(methacryl-oxyethoxy)phenyl] propane (bis-EMA), 2,2-bis[4-(methacryloxy)phenyl]-propane (bis-MA), and glycidyl methacrylate (GMA) is often manifested together with contact allergy to diglycidyl ether of bisphenol A (DGEBA) epoxy resin. To analyse patterns of concomitant
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.