472360

Sigma-Aldrich

Poly(oxy-1,4-phenylenesulfonyl-1,4-phenylene)

melt index 6 g/10 min (380°C/2.16 kg)

동의어(들):

Poly(1,4-phenylene ether-sulfone)

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(C12H8O3S)n
CAS Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

양식

granular

용융 지수

6 g/10 min (380°C/2.16 kg)

ISO 1628

50 mL/g, in phenol/1,2-dichlorobenzene(lit.)

전이 온도

Tg (DSC) 221 °C (onset)

solubility

aniline, dimethylacetamide and pyridine: soluble

density

1.37 g/mL at 25 °C (lit.)

SMILES string

Oc1ccc(cc1)S(=O)(=O)c2ccc(O)cc2

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Used in electrical connectors, printed circuit boards, sterilizable equipment and appliance covers.

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

예방조치 성명서

Hazard Classifications

Acute Tox. 4 Oral

Storage Class Code

11 - Combustible Solids

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

dust mask type N95 (US), Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Daniel Schneditz et al.
Clinical hemorheology and microcirculation, 58(3), 455-469 (2013-11-21)
It was the aim to examine the fluid flow in blood and dialysate compartments of highly permeable hollow fiber dialyzers where internal filtration contributes to solute removal but where excessive filtration bears a risk of cell activation and damage. Flow
Mario Bonomini et al.
Therapeutics and clinical risk management, 14, 1-9 (2018-01-04)
The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire
Wenhong Zhu et al.
Journal of visualized experiments : JoVE, (66)(66), e4108-e4108 (2012-08-17)
Although human saliva proteome and peptidome have been revealed they were majorly identified from tryptic digests of saliva proteins. Identification of indigenous peptidome of human saliva without prior digestion with exogenous enzymes becomes imperative, since native peptides in human saliva
Shengqiang Nie et al.
Colloids and surfaces. B, Biointerfaces, 100, 116-125 (2012-07-06)
In this study, a novel triblock copolymer of poly (styrene-co-acrylic acid)-b-poly (vinyl pyrrolidone)-b-poly(styrene-co-acrylic acid) (P(St-co-AA)-b-PVP-b-P(St-co-AA)) is synthesized via reversible addition-fragmentation chain transfer (RAFT) polymerization, and used for the modification of blood contacting surface of polyethersulfone (PES) membrane to improve blood
Shogo Takamuku et al.
ChemSusChem, 6(2), 308-319 (2013-01-12)
The morphologies and proton-transport efficiencies of segmented copoly(arylene ether sulfone) ionomers that contain tetrasulfonated sequences are compared with the corresponding copolymers with disulfonated sequences. Tetrasulfonated 4,4'-bis[(4-chlorophenyl)sulfonyl]-1,1'-biphenyl (sBCPSBP) is synthesized by metalation and sulfination. This new monomer is then used in

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.