콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

1.50764

Supelco

SeQuant ZIC®-cHILIC 100Å (3 µm) HPLC Columns

L x I.D. 20 mm x 2.1 mm guard Column Kit (3 pc) with coupler (1 pc)

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709
NACRES:
SB.52

제품명

SeQuant ZIC-cHILIC 3μm 20 x 2.1 mm Guard Kit, PEEK coated guard column 3 pc with coupler 1 pc

material

PEEK-lined stainless steel column

제품 라인

SeQuant

특징

endcapped: no

포장

pkg of 3 Columns with coupler 1 pc

파라미터

(pH 2 - 8)
at ≤70 °C
max. pressure at ≤550 bar

기술

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable

컬럼 길이 × I.D.

2 cm × 2.1 mm

Matrix

fully porous particle

기질 활성군

ZIC-cHILIC bonding phase

입자 크기

3 μm

공극 크기

100 Å pore size

분리 기술

hydrophilic interaction (HILIC)

일반 설명

The Guard column kit contains 5 SeQuant ZIC®-cHILIC guard columns including the fitting to connect to the analytical column.SeQuant ZIC®-cHILIC is designed for excellent HPLC and LC-MS of polar hydrophilic compounds. This zwitterionic stationary phase with phosphorylcholine functional group provides you with complementary selectivity for easier method development for substances that have been difficult to separate by previous types of HPLC columns operated in reversed-phase or HILIC mode.SeQuant ZIC®-cHILIC HPLC columns provide complementary selectivity to optimize separations of polar hydrophilic compounds. The columns carry a novel densely bonded, 1:1 charge-balanced phosphorylcholine functional group. As with all true zwitterionic stationary phases, straightforward and reproducible separations are achieved by hydrophilic partitioning combined with weak ionic interactions.The more accessible positive charges of SeQuant ZIC®-cHILIC columns enable selectivity tuning in chromatography through altered interaction with anionic and cationic molecular moieties. This can be favorable in several situations, for example in the separation of labile metal complexes or highly polar and multiply charged aminoglycosides. Their extraordinary stability and minimized bleed also make SeQuant ZIC®-cHILIC columns the preferred choice for many LC-MS applications.Learn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide Brochure: A Practical Guide to HPLC - Method Development Guide

법적 정보

SeQuant is a trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.