material
cellulose (thick pad)
clear Tenite™ plastic (housing)
mixed cellulose esters (MCE) membrane
polyethylene (plugs)
Quality Level
무균
non-sterile
필터 직경
37 mm
여과 면적
9 cm2
공극 크기
0.8 μm pore size
피팅
female Luer inlet slip
female Luer outlet slip
응용 분야
industrial qc
배송 상태
ambient
일반 설명
Fluid contamination analysis monitors are transparent, disposable, Tenite™ plastic filter holders, pre-assembled with mixed esters of cellulose membranes and absorbent cellulosic pads. The filter is sealed between the monitor sections with a thick cellulose pad under the filter to distribute sample flow evenly over the filter surface.
Matched-Weight Monitors remove the need for pre-weighing test filters in gravimetric analysis. Each monitor contains two superimposed filters matched in weight to within 0.1 mg. Sample passes through both, but all contaminant is retained on the upper (test) filter. Difference in filter weights, after drying, is the weight of contaminant in the sample.
For fluid contamination analysis monitors (not matched-weight), please see MAWP037P0.
Components (top to bottom):
Replacement parts
Matched-Weight Monitors remove the need for pre-weighing test filters in gravimetric analysis. Each monitor contains two superimposed filters matched in weight to within 0.1 mg. Sample passes through both, but all contaminant is retained on the upper (test) filter. Difference in filter weights, after drying, is the weight of contaminant in the sample.
For fluid contamination analysis monitors (not matched-weight), please see MAWP037P0.
Components (top to bottom):
- Yellow plug (polyethylene)
- Monitor top (Tenite)
- 0.8 μm MF-Millipore matched-weigh pair of filters, 37 mm (mixed cellulose esters)
- Thick absorbent pad, 34 mm (cellulose)
- Monitor bottom (Tenite)
- Red plug (polyethylene)
Replacement parts
- AAWP037PM | MF-Millipore™ Membrane Filter, 0.8 μm pore size (Monitor refills (matched weight pairs) with thick absorbent pads for liquid monitoring)
- AP30034P0 | Thick Absorbent Pad, 34 mm
- M000037P0 | Fluid Contamination Monitor, empty
애플리케이션
Use with Fluid Sampling Kit (XX6403730)
원리
Vacuum filtration
법적 정보
MF-Millipore is a trademark of Merck KGaA, Darmstadt, Germany
Tenite is a trademark of Eastman Chemical Company
Storage Class Code
11 - Combustible Solids
WGK
WGK 2