추천 제품
material
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
Quality Level
무균
non-sterile
제품 라인
Amicon®
제조업체/상표
Amicon® Ultra
파라미터
4 mL sample volume
기술
protein extraction: suitable
protein purification: suitable
길이
124 mm (4.88 in.)
직경
17.3 mm
여과 면적
3 cm2
용적
4 mL
공극 크기
10 kDa MWCO
배송 상태
ambient
일반 설명
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
애플리케이션
- Ultrafiltration with 10,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLC.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
- Size exclusion and protein fractionation.
특징 및 장점
- Ultracel® regenerated cellulose membrane with 10 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 5 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipette sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
법적 정보
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
Storage Class Code
10-13 - German Storage Class 10 to 13
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
프로토콜
Using a standard Amicon® Ultra centrifugal filter, a few rounds of diafiltration can efficiently remove unincorporated label from an antibody labeling reaction without diluting the sample.
소변 내 특정 단백질의 정확한 측정은 질병을 진단하고 관리하는 데 중요합니다.
Accurate measurement of specific proteins in urine is important for diagnosing and managing diseases.
표준 Amicon® Ultra 원심분리 필터를 사용하여 투석 여과를 여러 번 수행하면 항체 표지 반응에서 시료 희석 없이 미결합 표지를 효율적으로 제거할 수 있습니다.