추천 제품
Grade
for TLC derivatization
Quality Level
농도
0.2% in isopropanol
기술
thin layer chromatography (TLC): suitable
density
0.79 g/mL at 20 °C
SMILES string
[Cl-].CCN(CC)c1ccc2c(OC3=CC(\C=CC3=C2c4ccccc4C(O)=O)=[N+](\CC)CC)c1
InChI
1S/C28H30N2O3.ClH/c1-5-29(6-2)19-13-15-23-25(17-19)33-26-18-20(30(7-3)8-4)14-16-24(26)27(23)21-11-9-10-12-22(21)28(31)32;/h9-18H,5-8H2,1-4H3;1H
InChI key
PYWVYCXTNDRMGF-UHFFFAOYSA-N
애플리케이션
ready-to-use spray and dip reagent for chromatography
신호어
Danger
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
표적 기관
Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
53.6 °F - closed cup
Flash Point (°C)
12 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Journal of hazardous materials, 246-247, 135-144 (2013-01-10)
Amorphous TiO(2) (Am-TiO(2)) was prepared at room temperature by hydrolysis of Ti(OBu)(4) in water without addition of strong acids or organic solvents. Results from XRD and TEM revealed that the as-prepared Am-TiO(2) was composed of amorphous structure. For the simultaneous
Journal of hazardous materials, 244-245, 736-742 (2012-12-01)
The removal of Rhodamine B (RhB) by Co(x)Fe(3-x)O(4) magnetic nanoparticles activated Oxone has been performed in this study. A series of Co(x)Fe(3-x)O(4) nanoparticles was synthesized using a hydrothermal method. The synthetic Co(x)Fe(3-x)O(4) nanoparticles were characterized using X-ray diffraction (XRD) and
Chemical communications (Cambridge, England), 49(37), 3836-3838 (2013-02-19)
Hyperbranched polymers conjugated to a peptide-aptamer were prepared using a combination of RAFT polymerisation and click chemistry for targeting tumour cells in vivo. The polymers showed enhanced cell-uptake in vitro (compared to unconjugated polymer) while excellent specificity for solid tumours
Ultrasonics, 53(5), 1020-1032 (2013-03-19)
An acoustic trap with miniaturized integrated transducers (MITs) for applications in non-contact trapping of cells or particles in a microfluidic channel was characterized by measuring the temperature increase and trapping strength. The fluid temperature was measured by the fluorescent response
Scientific reports, 3, 1362-1362 (2013-03-02)
Optical microcavities are important for both fundamental studies of light-matter interaction and applications such as microlasers, optical switches and filters etc... Tunable microresonators, in which resonant modes can be manipulated, are especially fascinating. Here we demonstrate a unique approach to
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.