추천 제품
설명
non-ionic
Quality Level
분자량
average Mn ~362
refractive index
n20/D 1.451 (lit.)
density
0.95 g/mL at 25 °C (lit.)
HLB
9
SMILES string
CCCCCCCCCCCCOCCOCCOCCOCCO
InChI
1S/C20H42O5/c1-2-3-4-5-6-7-8-9-10-11-13-22-15-17-24-19-20-25-18-16-23-14-12-21/h21H,2-20H2,1H3
InChI key
WPMWEFXCIYCJSA-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Brij® L4 is a non-ionic surfactant. It comprises an alkyl (C12) tail attached to an oxyethylene headgroup.
애플리케이션
Brij® L4 has been used:
- as a surfactant for the synthesis of copper(I) oxide (Cu2O) spherical nanoparticles using a microemulsion technique
- as a non-ionic surfactant for preparing reverse micelles to synthesize Pt3Co alloy nanoparticles
- as a surfactant to enhance the efficiency of interfacial coupling of hydrophobic materials and to make hydrogel
생화학적/생리학적 작용
Brij® L4 exhibits amphiphilic properties. Brij L4 contains hydrophobic and hydrophilic regions that can form micelles and disperse hydrophobic drugs into the core of micelles. This in turn enhances drug solubility. Brij L4 also elicits a strong inhibitory effect against breast cancer resistance protein (BCRP) mediated drug efflux. It inhibits Taq adsorption better when compared to other commonly used surfactants. Brij L4 supports droplet polymerase chain reaction (PCR) in picoliter reaction volumes at standard Taq concentrations.
법적 정보
Brij is a registered trademark of Croda International PLC
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
이미 열람한 고객
Copper (i) oxide nanoparticle-mediated C-C couplings for synthesis of polyphenylenediethynylenes: Evidence for a homogeneous catalytic pathway
Catalysis Science & Technology, 11(7), 2414-2421 (2021)
Synthesis of Pt3Co alloy nanocatalyst via reverse micelle for oxygen reduction reaction in PEMFCs
Topics in Catalysis, 49(3), 241-250 (2008)
ACS applied materials & interfaces, 9(30), 25542-25552 (2017-07-12)
The emergence of stretchable electronics and its potential integration with textiles have highlighted a challenge: Textiles are wearable and washable, but electronic devices are not. Many stretchable conductors have been developed to enable wearable active textiles, but little has been
Annals of surgery, 255(2), 311-318 (2012-01-14)
To compare the safety and hypertrophy response after portal vein embolization (PVE) using 2 absorbable and 3 permanent embolization materials. Portal vein embolization is used to increase future remnant liver volume preoperatively. Application of temporary, absorbable embolization materials could be
AJR. American journal of roentgenology, 199(1), 200-207 (2012-06-27)
Balloon-occluded retrograde transvenous obliteration has been traditionally based on liquid sclerotherapy. However, overdose and systemic spillage of liquid sclerosant can cause severe complications, such as hemolysis, which lead to hemoglobinuria, allergy, acute respiratory distress syndrome, and other disorders. The purpose
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..