추천 제품
Grade
for GC derivatization
Quality Level
분석
99%
형태
liquid
품질
LiChropur™
반응 적합성
reagent type: derivatization reagent
reaction type: Acylations
기술
gas chromatography (GC): suitable
bp
69-70 °C/735 mmHg (lit.)
density
1.571 g/mL at 25 °C (lit.)
SMILES string
FC(F)(F)C(F)(F)C(=O)OC(=O)C(F)(F)C(F)(F)F
InChI
1S/C6F10O3/c7-3(8,5(11,12)13)1(17)19-2(18)4(9,10)6(14,15)16
InChI key
XETRHNFRKCNWAJ-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Learn more in the Product Information
Derivatization reagent used in a GC-MS analysis of stereoisomer content of synthetic peptides. Also used in a GC-MS detection method for synephrine in dietary supplements.
For the preparation of volatile pentafluoropropionyl derivatives of a wide range of compounds, for example, amines and alcohols, for EC/GC.
Pentafluoropropionic anhydride (PFPA) was used as derivatization reagent for urine samples to determine the presence of codeine, morphine, 6-monoacetylmorphine, ethylmorphine, and dihydrocodeine using GC-MS in selected ion monitoring (SIM) mode. It was also used to derivatize the dry pericardial fluid sample extracts for quantification of cocaine, benzoylecgonine, and cocaethylene in pericardial fluid using GC-MS.
포장
Clear borosilicate glass, high hydrolytic resistance (Type I)
법적 정보
LiChropur is a trademark of Merck KGaA, Darmstadt, Germany
신호어
Danger
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Skin Corr. 1B
보충제 위험성
Storage Class Code
8A - Combustible corrosive hazardous materials
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
이미 열람한 고객
Chirality, 18(7), 551-557 (2006-05-10)
Synthetic dipeptides comprising mixtures of enantiomers, diastereomers, or sequential isomers were converted into their N-perfluoroacetyl dipeptide esters (perfluoroacetyl: trifluoroacetyl, pentafluoroacetyl, heptafluorobutyryl; ester: methyl, 1-propyl, 2-propyl, 2,2,2-trifluoroethyl) and analyzed by GC-MS on the chiral stationary phases Chirasil-L-Val and Lipodex-E using helium
Journal of pharmaceutical and biomedical analysis, 41(4), 1468-1472 (2006-05-16)
A simple and rapid procedure based on gas chromatography-mass spectrometry (GC-MS) is described for determination of synephrine, active principle of Citrus aurantium plant, in solid and liquid dietary supplements. After the addition of 3,4-methylenedioxypropylamphetamine as internal standard (I.S.), a liquid-liquid
Comparison of RapiTest? with Emit? d, au? and GC-MS for the Analysis of Drugs in Urine.
Journal of Analytical Toxicology, 21, 49-53 (1997)
Analytical biochemistry, 216(2), 401-405 (1994-02-01)
We report an isotope dilution mass spectrometry method using capillary gas chromatography negative ion chemical ionization for the determination of cortisol in human plasma. Cortisol was derivatized with pentafluoropropionic anhydride at room temperature and measured by selected ion monitoring of
Journal of lipid research, 52(8), 1595-1603 (2011-05-24)
Estrogen metabolites play important roles in the development of female-related disorders and homeostasis of the bone. To improve detectability, a validated gas chromatography-mass spectrometry (GC-MS) method was conducted with two-phase extractive ethoxycarbonlyation (EOC) and subsequent pentafluoropropionyl (PFP) derivatization was introduced.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..